8
Pump specifications
8.1
Specification ratings
Operating temperature
5C to 40C (41F to 104F)
Storage temperature
530: -40C to 70C (-40F to 158F)
Humidity (non-condensing)
80% up to 31C (88F) decreasing linearly to 50% at 40C (104F)
Maximum altitude
2000m (6560ft)
Power Rating
530: 135VA
Supply voltage
100-120V/200-240V 50/60Hz 1pH (Subject to regional cord sets and
supply)
Maximum voltage fluctuation
+/-10% of nominal voltage. A well regulated electrical mains supply
is required along with cable connections conforming to the best
practice of noise immunity.
Full load current
530: <0.6A@ 230V; <1.25A @ 115V
Fuse rating
T2.5AH250V (5x20mm)
Installation category
(overvoltage category)
II
Pollution degree
2
IP
530: IP31 to BS EN 60529, if supplied with N module then IP66 to
BS EN 60529. Equivalent to NEMA 4X to NEMA 250 *(indoor use -
protect from prolonged UV exposure)
dB rating
530: < 70dB (A) @ 1m
Control ratio
530: 0.1-220rpm (2200:1)
Maximum speed
530: 220rpm
8.2
Weights
530
Drive only
+ 520R, 520R2
+ 520REL,520REM,
520REH
+ 505L
IP31
9.7kg
21lb
6oz
10.6kg
23lb
5oz
10.5kg
23lb 3oz
12.2kg
26lb
14oz
IP66
10.6kg
23lb
5oz
11.5kg
25lb
5oz
11.4kg
25lb 2oz
13.1kg
28lb
13oz
m-530en-en-01
13