Error code
Error condition
Suggested action
Er 3
FLASH corruption
Attempt to reset by switching power OFF/ON. Or
seek support.
Er 4
FRAM shadow error
Attempt to reset by switching power OFF/ON. Or
seek support.
Er 9
Motor stalled
Stop pump immediately. Check pumphead and
tube.
Power OFF/ON may reset. Or seek support.
Er10
Tacho fault
Stop pump immediately.
Power OFF/ON may reset. Or seek support.
Er14
Speed error
Stop pump immediately.
Power OFF/ON may reset. Or seek support.
Er15
Over current
Stop pump immediately.
Power OFF/ON may reset. Or seek support.
Er16
Over voltage
Stop pump immediately. Check supply.
Power OFF/ON may reset.
Er17
Under voltage
Stop pump immediately. Check supply.
Power OFF/ON may reset.
Er20
Signal out of range
Check analog control signal range. Trim signal as
required. Or seek support.
Er21
Over signal
Reduce the analog control signal.
Err50
Communication error
Attempt to reset by switching power OFF/ON. Or
seek support.