13.2
First-time start-up defaults
If the Auto Restart feature is enabled it may cause the pump to start as soon
as power is turned on.
Auto Restart only affects operation of Manual mode and PROFINET® mode.
If Auto Restart is enabled the "!" Symbol is shown on the screen to warn users
that the pump may operate without any manual intervention (pump resumes
with previous settings).
Do not use Auto Restart for more than:
•
1 mains power start per 3 minutes
We recommend remote control where a high number of starts is required.
If the pump is configured to Dispense or PROFINET® mode it will respond to
remote commands at any time including immediately after power on. The
pump may operate without any manual intervention (e.g. a remote setpoint
could start the pump with no key press required).
The pump is preset with operational parameters as shown in table below.
Table 8 - First-time start-up defaults
Parameter
530 default
Language
Not set
Default mode
Manual
Default manual speed
220 rpm
Pump status
Stopped
Max speed
220 rpm
Direction
CW
Pumphead
520R2
Tube size
9.6 mm
Tube material
Bioprene
Flow calibration
15.12 ml/rev
Flow units
rpm
Pump label
WATSON-MARLOW
Asset number
NONE
SG value
1
Keypad lock
Disabled
PIN protection
Not set
Keypad beep
ON
38
m-530pn-en-09 02-02-22