Version 1.0
PN: 2042-8198
Page 54 of 75
DN: 10-32813
27
0x1B
Logic
20
28
0x1C
Compare
20
36
0x24
Real Time Clock
1
45
0x2D
LED
4
68
0x44
Standard Bus
2
69
0x45
Modbus
2
If RMAP-2AXX-XXXX
70
0x46
Ethernet
1
74
0x4A
Alarm 2
10
75
0x4B
Control Loop 2
4
If RMAP-8AXX-XXXX
100
0x64
Consumer Data
16
101
0x65
Module Limit
1
If RMAP-8AXX-XXXX
102
0x66
Volume
3
210
0xD2
Optic Sensing
4
If RMAP-8AXX-XXXX
211
0xD3
Calibration
4
If RMAP-8AXX-XXXX
Figure 51 - Standard objects
New objects and deviations from standard EZ-ZONE objects are documented below. Standard EZ-ZONE
object documentation may be found in the user manuals for the EZ-ZONE RM family or the EZ-ZONE
COMPOSER® software.
Device
Device member 13
, “Load Parameter Set
,
”
includes an additional enumeration for applying factory
defaults. You may now choose to restore factory defaults with or without communication objects (and
others). Choose the “Factory” option (
default level 0) to exclude the following objects: Assembly,
Calibration, Standard Bus, Ethernet, Modbus®
and Real Time Clock. Choose the “Communications”
option to include the above objects (default level 1).
Device member 50
, “Command
,
”
is a special device command parameter. Writing the strings below will
result in the specified action.
Device member 51
, “Re
-Config,
”
will issue a re-config command to the RMA PLUS. This will bind all
object sources to their specified producers whether local or remote.
Device 1 (0x01), Instance 1
Member ID
Member Name
Data Type
Access
NV
Min
Max
Default
Comments / Description
13
0x0D
Load Parameter Set
ENUM16
RW
61
61: None
31: Factory
1234: Communications
50
0x32
Command
STRING
RW
""
""
- Empty String
"reset" -
Issue a soft reset (5 sec)
51
0x33
Re-Config
ENUM16
RW
59
59: No
106: Yes
Real-Time Clock
The RMA PLUS implements a real-time clock (RTC) with battery backup. The primary use of the time is
for the file system. You may optionally synchronize the RTC by using the
Key Features:
•
The RTC epoch begins 2000-01-01 00:00:00 UTC and ends 2135-12-31 23:59:59 UTC.
•
Supports time zone offset from UTC±00:00 (±12 hours, 15-minute increments).
•
If enabled and the RMA PLUS is powered-up, the RTC will automatically adjust the clock for Daylight
Saving Time (DST) following the currently established rules.
Summary of Contents for RMA PLUS RMAP-2A Series
Page 1: ...Version 1 0 PN 2042 8198 Page 1 of 75 DN 10 32813 RMA PLUS User Manual...
Page 8: ...Version 1 0 PN 2042 8198 Page 8 of 75 DN 10 32813...
Page 11: ...Version 1 0 PN 2042 8198 Page 11 of 75 DN 10 32813 Figure 3 Ground Wire Location...
Page 26: ...Version 1 0 PN 2042 8198 Page 26 of 75 DN 10 32813 Figure 22 RMA PLUS via USBD MICRO SD root...
Page 27: ...Version 1 0 PN 2042 8198 Page 27 of 75 DN 10 32813 Figure 23 RMA PLUS via USBD NOR FLASH root...
Page 42: ...Version 1 0 PN 2042 8198 Page 42 of 75 DN 10 32813 Figure 37 Default web page Index html...
Page 75: ...Version 1 0 PN 2042 8198 Page 75 of 75 DN 10 32813...