D8 Series User’s Guide
Chapter 4: Operation and Setup
62
Keypad
Access the setup menus (press and hold for 3 seconds).
Cancel a change without saving.
Escape from a parameter to a top-level setup menu.
Escape from a setup menu to the loop display or job display.
Acknowledge an alarm.
Toggle between the loop display and job display (if a job is loaded).
Edit a parameter value.
Scroll through the top-level setup menus.
Access the operator parameters (from the loop display).
Save a change and go to the next parameter.
Go to a different loop.
Save a change and go to a different loop.
Go to the scanning loop display (hold + for 3 seconds).
Save a change and go to the previous parameter.
Key
Description
Toggle between the loop display and job display (if a job is loaded).
Edit a parameter value.
Scroll through the top-level setup menus.
Clear RAM and set all parameters to defaults (hold during power up).
Get more information about the current screen.
>
x
<
,
.
p
i
l
01 Set point
r
b
1000˚C
Figure 4.2
– Keypad Navigation
Displays
Loop Display
The loop display shows detailed information about a loop.
01
925 ˚C
c
0
TO 1000man
h
100
Loop Name
Control Mode
Set Point
Process
Variable
Engineering
Units
Cool and Heat
Output Power
Figure 4.3
– Loop Display