8
WJ-8711A
(Maximum)
(Typical)
3-dB BW
Shape Factor
Group Delay Variation
(kHz)
(3/60 dB)
(100% of 3-dB BW)
0.3
1.35:1
50 µS
1.0
1.40:1
30 µS
3.2
1.25:1
30 µS
6.0
1.25:1
40 µS
16.0
1.25:1
60 µS
USB/LSB/ISB (3.2)
1.25:1
30 µS
IF Filter Specifications
MIL-STD-810D Test Method
A.
Low Temperature ......................................... Test Method 502.2
B.
High Temperature ......................................... Test Method 501.2
C.
Humidity ........................................................ Test Method 507.2
D.
Altitude ......................................................... Test Method 500.2
E.
Vibration ....................................................... Test Method 514.3
F.
Shock ........................................................... Test Method 516.3
Operating Temperature ........................................................ 0 to +50
o
C
Storage Temperature ........................................................... -40 to +70
o
C
Humidity ............................................................................... 10 cyclic days (240 hours); Procedure III for continuous
exposure to 95% RH
Altitude ................................................................................. 50,000 ft (15,240 meters) non-operating
24,000 ft (7,315 meters) operating
Vibration
(1)
A.
Basic Transporation (secure cargo)
Category 1 .................................................... Random vibration 1.04Gs non-operating (2 hours)
B.
Ground mobile (wheeled or
tracked vehicle) Category 8 ........................... Random vibration 6.0Gs operating (15 minutes)
C.
Marine (shipboard vessel not
specified) Category 9 ..................................... Random vibration 1.0Gs operating (2 hours)
D.
Environmental stress
(NAVMAT-P-9492) ....................................... Random vibration 6.0Gs operating (15 minutes for design
qualifications) 3.06Gs nonoperating [10 minutes for
production screening (ESS)]
Shock
(1)
................................................................................. Bench handling (field service) 8 drops total onto a horizon-
tal hard wooden surface, operating
MTBF .................................................................................... In excess of 10,000 hours; estimated in accordance with
MIL-HDBK 217E for Ground Fixed; +40
o
C environment
EMC ..................................................................................... EN50081-1 (radiated & conducted emissions to EN55022,
Class B)
EN50082-1 (including IEC 801-2:1984, IEC 801-3:1984
& IEC 801-4:1988)
EN55020 (Immunity for Receivers)
Safety .................................................................................... IEC 1010-1:1990+A1/EN61010:1993
Power Requirements ............................................................ 97 to 253 Vac (47 to 440 Hz)
Power Consumption ............................................................. 35 W, typical with options
Environmental Specifications