SETTINGS EXPLAINED:
•
ROTATE VIEW:
Rotate the view 180 degrees. The UP and DOWN buttons also swap when rotated. • With ROTATE VIEW highlighted, press
MENU to enter ROTATE VIEW setting. Use UP/DOWN to select desired setting and RETURN to confirm the setting and exit.
•
SPECIAL TEMP:
To temporarily heat spa to 105°F or 106°F once, and return to previous temperature setting. • With SPECIAL TEMP highlighted,
press MENU to enter SPECIAL TEMP setting. Use UP/DOWN to select the desired setting and RETURN to confirm the setting and exit.
•
HEAT MODE:
select STANDARD heating mode (polls every Energy Interval) for most users or ENERGY SAVING mode (polls every other
Energy Interval) or VACATION mode (set temp set to 60°F). • With mode highlighted, press MENU to enter setting. Use UP/DOWN to select
the desired setting and RETURN to confirm the setting and exit.
•
FILTER CYCLES:
set up filter cycle START TIME, DURATION, and DATE for filtering the spa. For FILTER CYCLE 1 and 2, if DURATION is set
to ZERO the system will do a purge cycle at the start time setting. • With FILTER CYCLE highlighted, press MENU to enter FILTER CYCLE 1,
2, 3, or 4. Select a FILTER CYCLE and press MENU again to enter the TIME/DURATION setting screen. In this screen, press MENU to move
between HOURS, MINUTES and DAYS; use UP/DOWN to change the values and RETURN to exit and confirm the setting. FILTER CYCLES 3
& 4 by default are OFF. To set them, enter START TIME, DURATION and enable ALL DAYS or a specific day for both FILTER CYCLES 3 & 4.
•
DATE-TIME:
set up Date and Time for the spa. • With DATE-TIME highlighted, press MENU to enter the DATE-TIME setting. In this screen,
pressing MENU will move and highlight various fields that can change the setting; UP/DOWN to change the values and RETURN to confirm
the setting and exit.
•
DEGREE F/C
: displays spa temperature in Celsius or Fahrenheit. This option is only available for 60 Hz countries. Unit automatically
displays Celsius for 50 Hz. • With DEGREE F/C highlighted, press MENU to enter the DEGREE F/C setting. Use UP/ DOWN to select the
desired setting and RETURN to confirm the setting and exit.
•
TIME DISPLAY:
displays spa time in AM/PM or 24 hour time. • With TIME DISPLAY highlighted, press MENU to enter TIME DISPLAY setting.
Use UP/DOWN to select the desired setting and RETURN to confirm the setting and exit.
•
DEVICES TIMEOUT:
allows changes to timeout setting for various devices. LIGHT can be set to a maximum of 4 hours; PUMP in high
speed and BLOWER can be set to a maximum of 1 hour; and PUMP in low speed can be set to a maximum of 2 hours. • With DEVICES
TIMEOUT highlighted, press MENU to enter and select various devices setting. Use UP/DOWN to select the desired time setting and
RETURN to confirm the setting and exit.
•
PANEL LOCK:
provides a choice to select PANEL LOCK for locking all panel buttons except MENU button; use TEMP LOCK to lock
UP/DOWN button for changing set temperature; and MENU LOCK to lock MENU button (push and hold MENU button more than 15
seconds to unlock the Menu). • With PANEL LOCK highlighted, press MENU to enter PANEL LOCK setting. Use UP/DOWN to select the
desired setting and RETURN to confirm the setting and exit.
•
NO HEAT TIME:
set the time frame for not allowing the heater to turn on. • With NO HEAT TIME highlighted, press MENU to enter the NO
HEAT TIME setting. In this screen, pressing MENU will move and highlight various fields that can change the setting; use UP/DOWN to
change the values and RETURN to confirm the setting and exit.
•
SERVICE MODE:
only available for Authorized Dealers and Spa Manufacturer.
•
DEMO MODE:
To demonstrate all device capabilities of the spa. • With DEMO MODE highlighted, press MENU to enter MODE setting. Use
UP/DOWN to select the desired setting and RETURN to confirm the setting and exit.
•
GENERAL INFORMATION:
Displays general information for the spa. • With GENERAL INFORMATION highlighted, press MENU to enter the
GENERAL INFORMATION menu. Use UP/DOWN to view different pages and information, press RETURN to exit the page. This screen will
indicate which plug should be inserted to correct side connector.
•
LANGUAGES:
To select various languages for the spa display. • With LANGUAGES highlighted, press MENU to enter and select a specific
language. Use UP/DOWN to select the desired setting and RETURN to confirm the setting and exit.
•
SERENITY MODE:
Set to turn off all outputs and provide quiet while in the spa. • With SERENITY MODE highlighted, press MENU to enter
and select a specific time. Use UP/DOWN to select the desired time setting. Press MENU again to navigate to EXIT/START. Select the
desired option and RETURN to confirm the setting and exit.
•
ENERGY INTERVAL:
Only available for Non-Circ systems. • With ENERGY INTERVAL highlighted, press MENU to enter the ENERGY INTERVAL
setting. Use UP/DOWN to select the desired minutes setting and RETURN to confirm the setting and exit.
•
SILENT TIME (FUNCTIONS PAUSE):
Only available for Non-Circ systems. Set the time frame for no polling during night or other desired
periods. • With SILENT TIME highlighted, press MENU to enter the SILENT TIME setting. In this screen, pressing MENU will move and
highlight various fields that can change the setting; use UP/DOWN to change the values and RETURN to confirm the setting and exit.
•
CLEANER CYCLE:
Only available for Non-Circ systems. To turn on filtration after using the spa for short cleaning period. • With CLEANER
CYCLE highlighted, press MENU to enter and select a specific duration. Use UP/DOWN to select the desired time setting. Press Menu
again to navigate to Exit/Start. Select the desired option and RETURN to confirm the setting and exit.
•
BLUETOOTH
: Only available with Bluetooth module in the system. To use the control panel and play music from mobile devices. • With
BLUETOOTH highlighted, press MENU to enter BLUETOOTH menu. In this screen, use UP/DOWN to select an option and MENU will execute
or enter the selected option. Press RETURN to exit BLUETOOTH menu.
•
RESET WI-FI
: Only available with Wi-Fi module in the system. This is used to reset Wi-Fi module. • With RESET Wi-Fi
highlighted, press MENU to enter. Use UP/DOWN to select the desired setting and RETURN to confirm the setting and exit.
6