background image

MOTOR WIRING

1.   Before working on any electrical connections be sure that the power is turned off.
2.   All wiring must conform to local, state and/or national codes.
3.   All wiring must conform to wiring diagram on the motor nameplate or on the back of the terminal cover.
4.  Incoming line voltage must be within 10% of the nameplate voltage.
5.  A solid copper bonding conductor no smaller than No. 8 AWG should be connected from the wire connector  
  on the motor to all metal parts of the spa or hot tub structure, and, to all electrical equipment, metal conduit,  
  and metal piping within five feet of the inside walls of a swimming pool, spa or hot tub when the motor is  
  installed within five feet of the inside walls of the spa or hot tub.
6. 

DO NOT

 ground to a gas supply line. 

7.   Ground motor prior to connecting to electrical power.
8.  Improper grounding can cause serious injury and damage to the motor, voiding the warranty. 

230V

1-Speed

Black

(Power)

Green (Ground)

IRON MIGHT PUMP INSTRUCTIONS

ALL ELECTRICAL INSTALLATIONS SHOULD BE PERFORMED BY QUALIFIED ELECTRICIANS

• 

WARNING

: Risk of electrical shock. Connect only to a Ground-Type Receptacle protected by a Ground-Fault Circuit 

  Interrupter (GFCI). Potential risk of fire, electric shock or injury to person if misused. Do not install within an outer  
  enclosure or beneath the skirt of the spa unless so marked.

• 

WARNING

: To reduce the risk of injury, do not permit children to use this product unless they are closely  

  supervised at all times.

• 

CAUTION

: This pump is for use with permanently installed pools and may also be used with hot tubs and spas  

  if so marked. 

Do not use with storable pools.

 A permanently installed pool is constructed in or on the ground  

  or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it  
  may be readily disassembled for storage and reassembled to its original integrity.

INSTALLATION INSTRUCTIONS

LOCATION

: Place pump on level surface. Pump must be installed below water surface. Shut off valves should be 

installed on both the inlet and outlet of the pump for future maintenance. Installation area should be clear of any 
direct water and have adequate floor drainage. Pump should be protected from excessive moisture. Allow access 
area large enough to service both pump and plumbing.

The inlet and outlet have Waterway male union threads. Use Waterway tailpiece assemblies for best connection. 
These unions allow the pump to be removed for service without disturbing the plumbing. 

HAND TIGHTEN UNIONS ONLY! DO NOT USE A WRENCH OR ANY ADHESIVES OR SOLVENTS!

DO NOT

 use pipe sealant. Use only Teflon tape or other sealing compounds approved for use with plastic. Some 

pipe sealants not approved for use with plastic will cause stress cracking of plastic parts. New installations often 
require plumbing inspections. This inspection is usually conducted using city water pressure. A pressure regulator 
should be used when preforming this test and should not exceed 40 PSI during the pressure test. When the filter 
and pump are under pressure, insure that all air is removed from the system. Extreme care must be taken during the 
pressure test.  

FAILURE TO FOLLOW THESE INSTRUCTIONS EXPLICITLY CAN RESULT IN PERSONAL INJURY AND 

WARRANTIES WILL BE VOIDED.

IMPORTANT SAFETY INSTRUCTIONS & WARNINGS • SAVE THESE INSTRUCTIONS • PLEASE READ AND FOLLOW ALL INSTRUCTIONS

2200 East Sturgis Road, Oxnard, CA  93030 • Ph. (805) 981-0262 • Fax (805) 981-9403

www.waterwayplastics.com • [email protected]

810-0231.0410

© 2010 Waterway Plastics

WARRANTY

The Iron Might pump will receive a limited warranty from any defect in material or workmanship of one year from the date of manufacture. This includes the motor, 

but not the motor seal. Products that fail or become defective during the warranty period, except as a result of improper installation, bad water chemistry, accidents 

or negligence on behalf of the owner, freezing, earthquakes, fire, floods or other acts of nature, shall be repaired or replaced at Waterway’s option without charge 

to the owner. This process will be completed within 90 days of receipt of the defective product barring delays caused by the acquisition of component parts not 

manufactured at our facility. To obtain warranty replacements or repair, defective products should be returned (transportation paid) to the place of purchase, or to 

Waterway. It should include a description of the defect and the circumstances surrounding the incident or problem. Warranty begins on the date of manufacture. 

Waterway shall not be responsible for cartage, removal and/or reinstallation labor, or any other such costs incurred in obtaining warranty replacements This warranty 

gives you specific legal rights. You may also have other rights which vary from state to state.

White

(Common)

115V

1-Speed

Black (Power)

Green (Ground)

1

2

Ensure wiring circuit agrees with diagram and leads are securely tight.

Reviews: