Waterway 600-0111 Installation Instructions Download Page 2

SERVICEABLE SWING CHECK VALVE REPLACEMENT PARTS

SWING CHECK VALVE LOCATION

• 

Water flow 

MUST 

be in the direction of the arrow.

IMPORTANT:

 Locate the Swing Check Valve at the lowest 

possible position in the plumbing system. Allow for a 
minimum of 18" water column. The weight of the water 
column assists in a greater valve seal and function.

MAINTENANCE

The clear cover permits easy inspection of the Swing 
Check Valve. If necessary, the valve can be disassembled 
for inspection of the o-ring and valve assembly. Before 
reassembly, lubricate o-ring thoroughly with appropriate 
silicone lubricant.

#  

Part No.  

Description

1  

819-0025

  

Screws 

(8 required) 

2  

605-0111

 

Lid & Flapper Assembly

3  

805-0241

  

O-Ring

4  

N/A

  

Body 

(must purchase complete valve)

--  

810-0270

  

Instruction Sheet

810-0270.0310

© 2010 Waterway Plastics

18" Minimum 

Recommended

Flow

Swing Valve 

Assembly

1

2

3

4

3" Swing Check Valve Assembly Performance Curve

Flow Rate (GPM)

Pr

essur

e D

iff

er

ential (PSI)

0

50

100

150

200

250

0

1

0.2

1.2

0.4

0.6

0.8

Reviews: