35
|
53
Configuring the Pressure Governor—User Configuration Mode
1
2
3
4
6
5
Use the illustration and instructions to open the
configuration mode, change parameters, and exit
the configuration mode. Configure the pressure
governor with the appropriate parameters for your
application. For a description of the available
parameters in this mode, refer to:
The menus are divided into 3 levels of access: user,
service, and OEM. The user configuration mode
gives you access to the user level settings. The
service configuration mode gives you access to the
service level settings, as well as the user level
settings. The OEM configuration mode gives you
access to all the settings. Follow the instructions
below to access the user configuration mode.
1 From ready mode, press and hold the
Preset
and
Idle
or
Preset
and
Status
buttons for 5
seconds to enter the user configuration mode.
2 The RPM display shows P and the selected
parameter number when in the configuration
mode.
3 Use the
PSI
and
RPM
buttons to change the
parameter number.
4 Use the
+
and
–
buttons or the
Rotary Knob
to
change the parameter value.
5 Press the Preset button to store the parameter
value.
6 Press the
Idle
or
Status
button to exit the
configuration mode.