Product Overview
Operation
Connecting the Priming Valve
1
M
M
M
F
F
F
3
2
4
7
5
6
Use the illustration and instructions to install the
priming valve. To connect to the apparatus
plumbing, refer to:
1 Connect the split CANbus cable to the CANbus
connector on the priming valve motor cable.
2 Connect the male end on the split CANbus
cable to an upstream node controller, or to the
PDM control box—the discharge CANbus
connection.
Note:
Use a CANbus extension cable if
necessary.
3 Connect the female end on the CANbus splitter
cable to next downstream node controller, or to
a terminating resistor if this is the last
downstream node controller in the system.
Note:
Use a CANbus extension cable if
necessary.
4 Locally source a Deutsch DT06-2S connector
and an appropriate cable to connect apparatus
power to the priming valve motor cable. Power
the priming valve motor through a 10 A circuit
breaker.
5 Connect the priming valve inlet to the
concentrate supply line.
6 Connect the priming valve outlet to the
concentrate supply tank.
7 Connect the priming valve motor cable to the
priming valve.
I-2254 L-1222-4