background image

 

WL290

 Manual 

                                                                    Page 57   Revision 9‐3‐2019 

HOT WATER TROUBLESHOOTING INDEX 

  

1.

 

Hot Water is not Hot 85°C (185°+/‐ 5°F) 

  

Included in this section are the Two Resettable Hot Tank Overloads (High Limit Safety) 
Instructions. 

 
 

1.

 

Hot Water is not Hot 85°C (185° +/‐ 5° F) 

 

 

The Hot temperature set point is 85°C (185° F) and is controlled by a thermistor in the well of 
the Hot Tank.   

 

There are two Hot Tank Overload Devices (High Safety Limit) on the side of the Hot Tank that 
will trip to prevent damage to the unit if the tank is dry heated (turned on without water in 
it). 

 
 

It typically takes 10 minutes for the 500W to heat the 1.6 Liter of room temperature 
(ambient) water to the 85°C (185° F) set point.

 

 

Possible Reason 

Solution 

No power to heater elements 

Check that the Red Heater and Compressor 
switch is on. 
 
Turn Red Heater and Compressor Switch on.   

I = ON

 

Hot Tank Overload Devices 
(High Safety Limit) tripped   
 

Hot Tank Overload Devices 
(High Safety Limit) is a safety 
feature to ensure the tank does 
not overheat. 

Hot Tank Overload Devices (High Safety Limit) will “click” 
when pushed.  The Hot Tank Overload Devices (High 
Safety Limit) are automatically reset when pressed.   
 

See Resetting

 

Hot Tank Overload Devices (High Safety 

Limit) Instructions that are included further below in this 
Troubleshooting Section

 

Hot Tank Overload Devices 
(High Safety Limit) “open” on 
Hot Tank 

Turn Power off.   
 
Check OHM’s resistance across terminals on each of the 
Hot Tank Overload Devices (High Safety Limit) separately. 
Good components will indicate a closed circuit or zero 
OHM’s on the meter. 
 
Replace components as necessary. 

Loose or improperly connected 
wire(s) to the heating element / 
hot tank. 

Visually inspect wire leads gong to the hot tank; confirm 
proper connections to the heating elements. 
 
 Hot tank life is 3‐5 years, depending on usage.   
 

Reviews: