PRE-DELIVERY PROCEDURES
DANGER!
ELECTRICAL SHOCK HAZARD.
Only qualified personnel who have read and understand this entire manual should attempt to
install, or service this unit, failure to do so could result in death or serious injury.
WARNING!
ALWAYS SANITISE BEFORE USE.
Sanitise before use to eliminate any potential microbiological contaminates.
Red Compressor/Heater Switch must be in the O=OFF position while the Hot
Tank is empty. Damage could occur within one minute and the overheat
(high limit) will require manual reset if heater is turned on with an empty Hot
Tank.
Sanitization of Machine
Materials Needed:
•
Personal Protective Equipment. Rubber or Nitrile Safety Gloves and Protective Eyewear
•
Phillips Screwdriver
•
Sanitiser – Aquadosa Or equivalent (5.25% Sodium Hypochlorite)
•
Unused sponges or paper towels
•
Dish Soap
•
Clean water
1.
Unpack the
Waterlogic WL1000GF MAX Water Treatment System
and check exterior for
damage.
CAUTION!
ALWAYS SANITISE THE INTERNAL PLASTIC RESERVOIR, LID AND FLOATS PRIOR
TO INSTALLATION.
The internal wetted surfaces of the machine have been handled multiple times in the process of
manufacturing. By following the steps below, you will ensure the cleanliness and sterility of the
drinking water
2.
Remove the Top Cover of the
WL1000GF MAX Water Treatment System
.
The two screws securing the Top Cover are located in each rear corner.
3.
Remove the Reservoir Tank Cover to access the Reservoir Tank.
Reservoir Tank Cover
Reservoir Tank