Owner's Manual

This Manual is for the Installation, Operation,

and Maintenance of the

WATER FACTORY SYSTEMS

CoolerMATE

Reverse Osmosis Systems

Model CMTRO-75

 

.

.

System tested and certified by NSF International against 
NSF/ANSI Standard 42 and Standard 58 for the claims 
specified on the Performance Data Sheet.

Installer: Please leave this manual with owner/operator.
End User: Please retain for operation and future maintenance instructions.

Summary of Contents for CoolerMATE CMTRO-75

Page 1: ...olerMATE Reverse Osmosis Systems Model CMTRO 75 System tested and certified by NSF International against NSF ANSI Standard 42 and Standard 58 for the claims specified on the Performance Data Sheet Installer Please leave this manual with owner operator End User Please retain for operation and future maintenance instructions ...

Page 2: ...37 6501 24 hours To reduce the risk associated with ingestion of water contaminated with sanitizer After installation sanitizer MUST be flushed from the system before first use as directed within the installation instructions To reduce the risk of injury associated with household bleach Read and follow manufacturers directions and cautions Keep out of reach of children DO NOT intermix with other c...

Page 3: ...ing to cooler Filter Icon Feedwater Inlet 1 4 Green Polyethylene Tubing with Flow Control Assembly To StorageTank 3 8 Yellow Polyethylene Tubing Back View of Bracket Drain Line Green Tubing Flow Control Assembly Back View of RO Cartridge 1 2 Flow Control RO Drain Line Construction 1 Insert the thin flow control tubing with attached bushing and stop into the 1 4 green tubing 2 Insert the green tubi...

Page 4: ...There are two slots with keyholes to provide a variety of options for bolting or hanging the CMTRO 75 system on the cooler In some cases existing screws can be used Further there are keyholes for those who desire to install studs bolts or screws at the required spacing to allow easy removal of the entire system Make tubing connections With the CMTRO 75 system fastened to the cooler the tubing conn...

Page 5: ...he end of the threaded tank stem Install the 3 8 x 1 4 tank valve onto the threaded tank stem Do not overtighten 2 Disconnect the 3 8 yellow tubing from the back of the filtration assembly and connect one end of it into the tube fitting located on the tank valve 3 Connect the other end of the 3 8 yellow tubing to the 3 8 x 1 4 union connector included in the tank sanitization kit 4 Connect the fre...

Page 6: ...ion and Maintenance Instructions Replacing the Filter Cartridges The life of the prefilter cartridge generally depends on the local water conditions i e sediment rust and or chlorine levels while the life of the postfilter cartridge s is generally determined by the length of service It is recommended that the cartridges be replaced as noted below When to Replace the Sediment Carbon Prefilter Cartr...

Page 7: ...completely depressurize 2 Make sure that there is some slack in the green tubing connected to the fitting at the bottom of the RO membrane cartridge Twist the cartridge 1 4 turn to the left so that the tubing connection is accessible See illustration on the right 3 Remove the green tubing by depressing the small white collet and pulling the tubing away from the fitting Note It is advisable to chec...

Page 8: ...800 733 1199 Worldwide 1 203 237 5541 Fax 1 203 238 8701 www waterfactorysystems com www cuno com 2009 3M Company All rights reserved CUNO CMTRO 75 and Water Factory Systems are trademarks of 3M Company used under license NSF is a trademark of NSF International a 3M company ...

Reviews: