background image

 

 

Maintenance / Warranty Information 

All BrassMaster Plus water treatment systems 

feature  the  Assured  Performance  Modular 

(APM) design. If you experience a failure of 

any  valve  component,  the  brass  module  can 

be easily removed and replaced.  

Reference  the  BrassMaster  and  BrassMaster 

Plus Technical Video Library on our website 

(link is provided below) for detailed steps on 

how  to  remove  the  module.  The  required 

(downloadable)  form  to  have  your  module 

replaced is also located at this site. 

Please  contact  your  dealer  or  Water  Control 

Corporation for module support.  

Nearly all  serviceable  

parts lie within the  

removable / replaceable 

APM module.  

This eliminates costly and 

time consuming field repairs. 

For factory module support contact: 

Water Control Corporation 

7150 143

rd

 Ave NW 

 Ramsey, MN 55303 

Phone: 1-866-405-1268 

 Fax: 763-427-5665 

www.watercontrolinc.com

 

IMPORTANT

: Test your water 2x annually (every 6 months)  to ensure proper system operation!  

Two postage pre-paid test bottles included! 

To reorder, visit 

watercontrolinc.com/nitramax-nitrate-removal

 or scan this QR code:  

BrassMaster and BrassMaster Plus Technical Video Library:

 

 https://watercontrolinc.com/residential-technical-support/residential-technical-videos

 

BrassMaster technical videos demonstrate how to set up or remove the control module. If replacing your 

control module, please use the (downloadable) 

Module Order Form

.

 

Salt Maintenance 

Failure to maintain salt in the brine tank will allow nitrates into your water! 

You must keep salt in the brine tank. The salt tank operates best when the salt level is below 

half full. Excessive brine tank filling may cause a salt “bridge” to form. The salt pellets wedge 

against each other preventing the salt pellets from fully submersing. This will prevent a proper 

brine solution from forming which will not allow the NitraMAX to regenerate properly. The 

NitraMAX will regenerate but not recondition the media. A salt bridge can be broken up using a 

broom handle or similar rod. Carefully pound it into the salt and the pellets will collapse. After 

loosening the salt pellets wait 2 hours and start a manual regeneration. A second system regen-

eration may be needed to fully recondition the media. You should only use sodium chloride or 

potassium chloride pellet salt for NitraMAX systems. Other types of salt (rock or snow melting) 

will contain dirt and chemicals that will affect your system. 

Summary of Contents for Brassmaster Plus+ NitraMAX LS Series

Page 1: ...er visit watercontrolinc com nitramax nitrate removal or scan this QR code BrassMaster and BrassMaster Plus Technical Video Library https watercontrolinc com residential technical support residential technical videos BrassMaster technical videos demonstrate how to set up or remove the control module If replacing your control module please use the downloadable Module Order Form LS MODELS ...

Page 2: ...with system Nitrate Nitrite Sulfate Filter Capacity Calculation Multiply nitrate and nitrite concentration PPM by 0 0474 to calculate Grains per Gallons of nitrate and nitrite PPM mg L Specifications NM 150 LS NM 250 LS Nitrate Nitrite Sulfate capacity raw water PPM 100 100 Anion nitrate media cu ft 1 5 2 5 Max iron raw water PPM 0 0 Service flow rate GPM 8 13 Water used per regeneration gals 70 8...

Page 3: ...nd of drain line fitting and run to a nearby drain IMPORTANT It is highly recommended that a hose clamp be used to secure tubing to drain fitting to ensure tubing from being removed during elevated pressure situations Be sure not to submerse drain line end into drain as an 1 1 2 minimum air gap must be maintained to prevent potential backflow hazard Firmly secure at drain while maintaining a minim...

Page 4: ...and let go display will indicate BF Brine Fill cycle Allow timer to fill the brine tank for the entire time on the display The unit will advance to the service position when completed Push extra cycle button for 5 seconds this will start a manual regeneration from start to finish This will take approximately two hours Start up procedure is now complete The unit is now pressurized with water and re...

Page 5: ...uals the day override setting This ensures regular regeneration periods Recom mended standard setting is 14 days Setting Current Time Day 1 Press either the Up or Down buttons to adjust current time of day by one digit Press and hold either the up or down button to adjust current time of day display by several digits Ensure the AM PM setting matches the current time of day Start Up Procedure Abbre...

Page 6: ...n Set the system capacity in Grains per Gallon as calculated on page 2 round up to the nearest whole num ber This will determine the amount of water usage allowed between regeneration cycles 5 Set Fixed Reserve Capacity Press the Extra Cycle button to advance to next option Set the Fixed reserve capacity for the household This is the amount of water needed in reserve to reach the delayed regenerat...

Page 7: ...ster Plus Technical Video Library https watercontrolinc com residential technical support residential technical videos BrassMaster technical videos demonstrate how to set up or remove the control module If replacing your control module please use the downloadable Module Order Form Salt Maintenance Failure to maintain salt in the brine tank will allow nitrates into your water You must keep salt in ...

Page 8: ... FITNESS FOR A PARTICULAR PURPOSE WHAT IS NOT COVERED BY THESE WARRANTIES 1 Conditions damages and health effects resulting from any of the following Wear or malfunction caused by unfavorable water conditions Improper installation delivery or maintenance Any repair modification alteration or adjustment not authorized by the manufacturer or an authorized servicer Misuse abuse accidents or unreasona...

Reviews: