2
Warning!
Consuming water with combined nitrate/nitrite levels above the USEPA MCL (Maximum Con-
taminant Level) of 10 PPM (10 mg/L) can cause breathing/oxygen absorption problems in in-
fants and animals — and may be linked to certain cancers.
Always install and operate this system according to manufacturer instructions. Test water every
six months to verify proper system operation.
Water Control offers inexpensive, non-certified test services (the first 2 test bottles are included
free with system).
Nitrate (+ N Sulfate) Filter
Capacity Calculation
Multiply nitrate and nitrite concentration (PPM*) by 0.0474 to calculate Grains per Gallons of
nitrate and nitrite
*PPM=mg/L
Specifications
NM-150-LS
NM-250-LS
Sulfate capacity (raw water) (PPM)
100
100
Anion (nitrate) media (cu.ft.)
1.5
2.5
Max iron (raw water) (PPM)
0
0
Service flow rate (GPM)
8
13
Water used per regeneration (gals)
70
85
Salt used per regeneration (lbs)
8
13
Max hardness (raw water) (GPG)
3
3
IMPORTANT
: Test your water 2x annually (every 6 months) to ensure proper system operation!
Two postage pre-paid test bottles included!
To reorder, visit
watercontrolinc.com/nitramax-nitrate-removal
or scan this QR code: