Catalyst monitor with programmed audio signals

Models 9-90 and 9-90AC Fahrenheit temperature display
for catalytic wood-burning stoves & fireplaces

Owner’s Manual

Condar Company • 111 Kangaroo Drive • Columbus, North Carolina 28722 • 828.436.2102 •Condar.com

Model #9-90

Summary of Contents for 9-90

Page 1: ...st monitor with programmed audio signals Models 9 90 and 9 90AC Fahrenheit temperature display for catalytic wood burning stoves fireplaces Owner s Manual Condar Company 111 Kangaroo Drive Columbus North Carolina 28722 828 436 2102 Condar com Model 9 90 ...

Page 2: ...tery types Two batteries operate in parallel not in series To install optional second battery push down don t remove the foam Remove insulator cap from second pair of connector wires to install a second battery 3 Where to locate the electronic monitor The 6 foot thermocouple cable allows you to locate Watchman monitor well away from stove or fireplace Don t place on any surface that will exceed 11...

Page 3: ... of temperature readings is unnecessary and consumes battery power 9 90 Condar s programming of Watchman s LED visual read out limits the temperature display to what s necessary during normal operation In the target operating zone of 700 to 1350 degrees you ll view your current temperature briefly once per minute automatically A single press to the manual DISPLAY TEMP button at any time commands c...

Page 4: ...nger still achieving a pretty fire by adjusting draft to bring temperatures down The nice thing is when your catalyst is engaged even an apparent smoky fire is environmentally responsible because the combustor takes care of transforming smoke into extra heat with the only emissions being minor water vapor and carbon dioxide Display flashes every 1 minute power dot flashes every 3 seconds To activa...

Page 5: ...o out After you return your stove or fireplace to target temperature operating zone the AUDIO SIGNAL feature will resume automatically and the dot will illuminate Intermittent beep code can be muted by pressing Audio Signal CATALYST DESTRUCTION and SAFETY At 1600 degrees continuous warning beep code begins This audio warning cannot be manually shut off even by pressing the AUDIO SIGNAL button When...

Page 6: ...es as to fitness of purpose installation by consumer purchasers or by resellers or consequential damages to other equipment or properties Catalyst Maintenance For helpful tips about maintaining inspecting and replacing a catalytic combustor visit WoodstoveCombustors com Operation_Tips html Catalyst Failure When a catalyst is engaged emissions from a chimney flue should look like white steam Dirty ...