Introduction:
This guide aims to give you a quick overview of the 5 basic steps required to install your Watchguard Digital
Security System, as well as its basic operation. It is important that you follow the step-by-step instructions
detailed in the full installation manual to ensure correct operation and full understanding of the system.
Once the locations for the main control unit and siren are chosen, connect power supplies and turn on the main
control box key switch and the siren key switch. Now test their operation before mounting the units permanently
to ensure that they are within the wireless radio range.
STEP 1.
MAIN CONTROL UNIT
Choose a convenient mounting location to install the main control
unit i.e. close to a phone outlet and power point. Drill mounting
holes (7mm Diameter) into the chosen location. Mount the unit on
the wall using the supplied screws and wall plugs.
CONNECTIONS
Remove cover plate then connect the phone line into the left side
phone socket. If you are using a phone / fax / PC already at your
available phone point, you may plug the lead from your existing
device into the right side socket. Plug the power supply into a
power point and switch on. Straighten the wire antenna for
maximum wireless range. Now turn the main key switch to the
ON position (do not press the remotes).
WATCHGUARD DIGITAL V2
Quick Start Guide
Antenna
ON
OFF
AC POWER
SOCKET
STEP 2.
WIRELESS PIR DECTECTORS
Power the detector by
opening the case and
removing the plastic
insert
between
the
battery terminals. Wait 3
minutes for the detector
to warm up. During this
time you can work out
where you would like to
locate your detectors.
To test each detector’s
mounting location:
Put DIP switch 1 and 3
on the Main Control Unit
up. While holding the
detector in the mounting
position open and close
the detector case.
The main unit will beep
once. If the detector
passes, you will hear a
second set of beeps a few
seconds later. If this does
not occur, you must
reposition the detector
and retest.
Now you can mount your
detectors. Drill a 5mm
diameter hole into the
wall. Push the wall plug
into the hole then screw
in the mounting bracket.
The detector can now be
pressed onto the swivel
bracket.
Re-test
the
detector by opening &
closing the case and then
walking
back
and
forward in front of the
detector. The main unit
will beep each time the
Red PIR Detection LED
illuminates.
When completed for each individual detector, return all the
main unit dipswitches to off to exit this test mode.
Ph
on
e
L
in
e
Power supply
Cover
Plate