background image

Hardware Description

Device Connections and Buttons

This table shows the device connections and buttons on the AP125.

Ethernet Network Interfaces

LAN2/PoE: Standard RJ45 connector that supports link speeds of 10/100/1000 Mbps and PoE
connectivity.

LAN1: Standard RJ45 connector that supports link speeds of 10/100/1000 Mbps. When managed by
Wi-Fi Cloud, you can configure this LAN interface as a wired extension for an SSID or for link
aggregation. For more information, see the

WatchGuard Wi-Fi Cloud Help

.

For APs managed locally by a Gateway Wireless Controller with Fireware v12.2.1 and higher, you
can bridge together the LAN ports on AP models that have two LAN interfaces. This enables you to
extend the wired network on the second LAN interface. For more information, see the

Fireware Help

.

Power Input (DC IN)

You can power the WatchGuard AP125 with 802.3af PoE on the LAN2 (PoE) interface.

You can also power the device with an optional AC power adapter.

WatchGuard AP125 Hardware Guide

4

WatchGuard Technologies, Inc.

Summary of Contents for AP125

Page 1: ...WatchGuard AP125 Hardware Guide AP125 Access Point ...

Page 2: ...ty providing best in class Unified Threat Management Next Generation Firewall secure Wi Fi and network intelligence products and services to more than 75 000 customers worldwide The company s mission is to make enterprise grade security accessible to companies of all types and sizes through simplicity making WatchGuard an ideal solution for Distributed Enterprises and SMBs WatchGuard is headquarte...

Page 3: ... Surface Bracket Optional 10 Connect the AP 12 Connect the AP for Link Aggregation 12 Ethernet Power Injector Optional 13 AC Power Adapter 15 Notices 16 Safety Notices 16 Product Safety Certification 16 Safety Warning 16 Disclaimer 16 HINWEISE ZUR SICHERHEIT 16 Sicherheitshinweis 17 AVISO DE SEGURIDAD 17 Certificación de seguridad del producto 17 Advertencia de seguridad 17 FCC Certification 18 CE...

Page 4: ...Declaration of Conformity Wireless 20 Brasil ANATEL 23 Mexico NOM 23 Taiwan Class B Notices 23 Taiwan NCC 23 Japan VCCI Notice Class B ITE 23 RoHS Statement 23 WEEE Statement 24 REACH Certificate of Compliance 24 WatchGuard Technologies Inc iii ...

Page 5: ...that support data rates of up to 876 Mbps and 300 Mbps respectively Requirements There are two ways you can manage your AP125 Total Wi Fi and Secure Wi Fi with WatchGuard Wi Fi Cloud A powerful cloud based enterprise wireless management solution for AP configuration security and monitoring Basic Wi Fi with WatchGuard Firebox Gateway Wireless Controller Local management configuration security and m...

Page 6: ... n 2 antennas 5GHz radio Ethernet Interface 1 x 10 100 1000 Mbps Gigabit Ethernet LAN2 802 3af PoE 1 x 10 100 1000 Mbps Gigabit Ethernet LAN1 for a wired extension of an SSID or link aggregation Power Interface Power over Ethernet 802 3af PoE PoE input voltage 48V Class 0 DC jack 12V DC input 1 5A 5 5mm overall diameter 2 1mm center pin hole Power Consumption Max 12 95 W Min 2 7 W Average 11 W MTB...

Page 7: ...ate clearance for air flow and cooling n Connect it to a surge protected power supply to prevent damage from sudden power changes Other environmental requirements Operating Temperature 0 C to 45 C 32 F to 113 F Operating Humidity 0 to 95 non condensing Non operating Temperature 20 C to 65 C 4 F to 149 F Non operating Humidity 5 to 95 non condensing WatchGuard Technologies Inc 3 ...

Page 8: ...ion for an SSID or for link aggregation For more information see the WatchGuard Wi Fi Cloud Help For APs managed locally by a Gateway Wireless Controller with Fireware v12 2 1 and higher you can bridge together the LAN ports on AP models that have two LAN interfaces This enables you to extend the wired network on the second LAN interface For more information see the Fireware Help Power Input DC IN...

Page 9: ... reset button through the hole To reset the device to factory default settings while the AP is powered on press and hold the reset button for up to 10 seconds until all LEDs go off to indicate that the AP has rebooted If you press the reset button while the AP is not powered on or is booting the reset button will have no effect WatchGuard Technologies Inc 5 ...

Page 10: ...n AP Firmware 8 8 1 and Higher LED Status Description Power Off Powered off Solid Green Powered on Flashing Green Not connected to Wi Fi Cloud or paired with a Gateway Wireless Controller No IP address received from DHCP LAN1 and LAN2 PoE Off No Ethernet link WatchGuard AP125 Hardware Guide 6 WatchGuard Technologies Inc ...

Page 11: ...f Solid green Powered on LAN1 Off No Ethernet link Solid amber Connected to LAN1 port at 10 100 1000 Mbps Flashing amber Activity on LAN1 port LAN2 PoE Off No Ethernet link Solid green Connected to LAN2 PoE port at 10 100 1000 Mbps Fast flash green Did not receive valid IP address from DHCP Slow flash green Cannot connect to Wi Fi Cloud or Gateway Wireless Controller Flashing green Activity on LAN...

Page 12: ... mounting bracket 15 16 24mm Part WG8027 to install the AP125 on a ceiling with a T rail Optional T rail mount brackets are available from WatchGuard n 9 16 T rail mount 15mm Part WG8026 n Interlude Silhouette T rail mount 15mm Part WG8021 WatchGuard AP125 Hardware Guide 8 WatchGuard Technologies Inc ...

Page 13: ...f the AP over the lower bracket notch and rotate into place 2 Make sure that all the mounting posts on the back of the AP are securely positioned in their bracket notches 3 To attach the bracket to the T rail rotate the bracket so it is parallel to the T rail and snap the bracket on the T rail WatchGuard Technologies Inc 9 ...

Page 14: ...tchGuard Part WG8040 1 Pull the release key outward to unlock the mount bracket 2 Attach the bracket to the mounting surface with screws not included 3 Attach the AP stubs to the bracket holders You may need to adjust the AP stubs for a firm fit WatchGuard AP125 Hardware Guide 10 WatchGuard Technologies Inc ...

Page 15: ...re Guide 4 Push in the release key to lock the hooks Make sure all hooks are locked in place 5 Use a T10 screwdriver to fasten the included screw to the release key to lock the AP to the bracket WatchGuard Technologies Inc 11 ...

Page 16: ...ble into the 12V DC power receptacle on the back of the AP125 4 Plug the power adapter into an 100V 240V 50 60 Hz AC power source Connect the AP for Link Aggregation With WatchGuard Wi Fi Cloud you can use both Ethernet ports of the AP125 for link aggregation that enables these ports to logically merge into a single link for higher aggregate bandwidth You must enable link aggregation in a device t...

Page 17: ...uard AP 1 Plug the Ethernet Power Injector into an AC power source 2 Connect an Ethernet cable from your network backbone for example a router switch or hub to the LAN connector on the Ethernet Power Injector 3 Connect an Ethernet cable from the LAN2 PoE Ethernet interface on the AP to the PoE connector on the Ethernet Power Injector The table below provides the specifications for the Ethernet PoE...

Page 18: ...data POE RJ 45 for 10 100 1000 Mbps data and power Voltage Pin4 5 54V Pin7 8 Return Indicator Power Green Temperature Operating 0 40 C 32 104 F Storage 30 80 C 22 176 F Humidity 5 90 Operating and storage Dimensions L 99 mm 3 9 W 68 5 mm 2 27 H 33 mm 1 3 Weight 149 6 g 0 33 lbs WatchGuard AP125 Hardware Guide 14 WatchGuard Technologies Inc ...

Page 19: ...s US EU UK and AU region specific adapter plugs AC Power Adapter Specs WatchGuard Part Number WG8041 AC Input Voltage Rating 90 264VAC Output Voltage DC 12V 1 5A Region Specific Adapter Plugs US EU UK AU Temperature Operating 0 45 C 32 113 F Storage 20 85 C 4 185 F Humidity Operating 0 95 Storage 0 95 WatchGuard Technologies Inc 15 ...

Page 20: ...13 Safety Warning n Do not place objects on the power cord n Do not obstruct the ventilation openings These openings prevent overheating of the machine n Never push objects of any kind into slots or openings on this equipment Making a contact with a voltage point or shorting out a part may result in fire or electrical shock n When removing or installing an appliance follow the general installation...

Page 21: ...a atentamente las siguientes instrucciones antes de utilizar el producto y se refieren a ellos como sea necesario para garantizar el funcionamiento seguro y continuo de su producto Información adicional se puede encontrar en la Guía del usuario electrónica Certificación de seguridad del producto El producto tiene certificación de seguridad WatchGuard bajo las siguientes normas n IEC 60950 1 2005 S...

Page 22: ...he user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter For operation within 5 15 5 25GHz 5 47 5 725GHz frequency range it is restricted to indoor environment The band from 5600 5650MHz will be disabled by the software during the manufacturing and cannot be changed by the end user This device meets all ...

Page 23: ... un fonctionnement indésirable Caution i the device for operation in the band 5150 5250 MHz is only for indoor use to reduce the potential for harmful interference to co channel mobile satellite systems ii the maximum antenna gain permitted for devices in the bands 5250 5350 MHz and 5470 5725 MHz shall be such that the equipment still complies with the e i r p limit iii the maximum antenna gain pe...

Page 24: ...MHz Sélection dynamique de fréquences DFS pour les dispositifs fonctionnant dans les bandes 5250 5350 MHz 5470 5600 MHz et 5650 5725 MHz For indoor use only Pour une utilisation en intérieur uniquement Radiation Exposure Statement This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distan...

Page 25: ...dio spectrum Matters ERM ElectroMagnetic Compatibility EMC standard for radio equipment Part 17 Specific conditions for Broadband Data Transmission Systems This device is a 5GHz wideband transmission system transceiver intended for use in all EU member states and EFTA countries except in France and Italy where restrictive use applies In Italy the end user should apply for a license at the national...

Page 26: ...WatchGuard AP125 Hardware Guide 22 WatchGuard Technologies Inc ...

Page 27: ...incluyendo la que pueda causar su operación no deseada Taiwan Class B Notices Taiwan NCC Japan VCCI Notice Class B ITE RoHS Statement The member states of the European Union approved directive 2002 95 EC Restrictions of Hazardous Substances RoHS directive that became valid on July 1 2006 It states that all new electrical and electronic equipment put on the market within the member states must not ...

Page 28: ...restriction of Chemicals came into effect on June 1 2007 REACH is Europe s new chemicals legislation which is applicable in all 27 EU Member States as well as the EFTA European Economic Area EEA REACH creates a new system for gathering information assessing risks to human health and the environment and authorizing or restricting the marketing and use of chemicals produced or supplied in the EEA RE...