Graphical Digital Panel Meter
WPMZ-1/3
RS-232C
Originalcommand/Originaloutput
communication manual
IM-0885-02
Ver.1.00
Watanabe Electric Industry Co., Ltd.
Page 1: ...Graphical Digital Panel Meter WPMZ 1 3 RS 232C Originalcommand Originaloutput communication manual IM 0885 02 Ver 1 00 Watanabe Electric Industry Co Ltd...
Page 2: ...composition 9 3 3 2 Communication example 9 4 ORIGINALCOMMAND 10 4 1 COMMON COMMAND TO WPMZ 1 AND 3 10 4 1 1 DSPA command 11 4 1 2 DSPB command 12 4 1 3 DSPC command 12 4 1 4 MESA command 13 4 1 5 MES...
Page 3: ...4 1 57 AMPAB OFF command 32 4 1 58 DEVA command 33 4 1 59 DEVA ON command 33 4 1 60 DEVA OFF command 33 4 1 61 DEVB command 34 4 1 62 DEVB ON command 34 4 1 63 DEVB OFF command 34 4 1 64 DEVAB command...
Page 4: ...MT3B command 48 4 2 16 MT4B command 48 4 2 17 WVCA command 49 4 2 18 WVCA ON command 49 4 2 19 WVCA OFF command 49 4 2 20 WVCB command 50 4 2 21 WVCB ON command 50 4 2 22 WVCB OFF command 50 4 2 23 W...
Page 5: ...fore setting and connecting When building the system carefully read the instructions of the product you use and other equipment and use it properly After reading this manual please keep it and read it...
Page 6: ...mmand communication specification and control and read necessary items Or if the communication protocol is unique and continuous output refer to 6 Unique continuous output response of the correspondin...
Page 7: ...onnecting to each module are as shown in the table below table 2 1 Communication specification WPMZ 1 3 standard based on RS 232C protocol OriginalCommand OriginalOutput Synchronization method Asynchr...
Page 8: ...9 30 31 32 33 table 2 2 terminal descriptions Terminal number symbol descriptions 28 RXD receive data terminal 29 TXD transmit data terminal 30 SG Signal ground 31 34 NC Do not connect 2 2 2 Connectio...
Page 9: ...mmand message the slave WPMZ sends a response message to the contents of the message The operations of the master side message and the slave side message are as follows 3 2 Communication procedure Pro...
Page 10: ...ps 50msec 3 3 Command format 3 3 1 Command composition It consists of the ASCII character string command part and delimiter part Control codes such as STX and ETX and error detection codes such as BCC...
Page 11: ...nd to WPMZ 1 and 3 The command of WPMZ 1 3 is explained below The delimiter is for CRLF If the delimiter is CR LF will be deleted Command notation 1 1 2 3 4 5 6 D S P A CR LF CR is Carriage return ASC...
Page 12: ...A L 1 CR LF Response In 0 9 display all the comparison outputs allocated to instantaneous value Ach are OFF 1 2 3 4 5 6 7 8 9 10 11 12 0 9 CR LF Response In 7 display AL1 and AL2 allocated to instant...
Page 13: ...lt is not output Calculated value of instantaneous value A instantaneous value B instantaneous value in the analog input specification is a numerical value of up to 5 digits and a numerical value afte...
Page 14: ...sponse of condition displaying 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 CR LF Response Response of condition displaying 0 0007 1 2 3 4 5 6 7 8 9 10 11 12 13 14 0 0 0 0 7 CR LF Response Set the decimal poi...
Page 15: ...responds to the instantaneous value display value of Bch Command 1 2 3 4 5 6 M E S B CR LF Response Same as MESA command 4 1 6 MESC command MESC is a command that responds to display value of instanta...
Page 16: ...14 15 16 17 A L 1 A L 2 A L 3 A L 4 CR LF Response Response of the case where the comparison output allocated to the instantaneous value Ach is OFF for all the channels 1 2 3 4 5 6 7 8 9 10 11 12 13...
Page 17: ...to the comparison result of instantaneous value of Bch Command 1 2 3 4 5 6 J G M B CR LF Response Same as JGMA command 4 1 9 JGMC command JGMC is a command that responds to the comparison result of th...
Page 18: ...1 2 3 4 5 6 C O M R CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instructions 1 2 3 4 O N CR LF 4 1 11 COMR ON command COMR ON is a command that instructs CompareReset WPMZ enters...
Page 19: ...and 1 2 3 4 5 6 H D R A CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 14 HDRA ON command HDRA ON is a command that instructs HoldReset Ach enters...
Page 20: ...Command 1 2 3 4 5 6 H D R B CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 17 HDRB ON command HDRB ON is a command that instructs HoldReset Bch ent...
Page 21: ...3 4 5 6 7 H D R A B CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 20 HDRAB ON command HDRAB ON is a command that instructs HoldReset Ach and Bch...
Page 22: ...nt value holding state Command 1 2 3 4 5 6 D H D A CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 23 DHDA ON command DHDA ON is a command that inst...
Page 23: ...nt value holding state Command 1 2 3 4 5 6 D H D B CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 26 DHDB ON command DHDB ON is a command that inst...
Page 24: ...ate Command 1 2 3 4 5 6 7 D H D A B CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 29 DHDAB ON command DHDAB ON is a command that instructs to hold...
Page 25: ...m value holding state Command 1 2 3 4 5 6 M A X A CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 32 MAXA ON command MAXA ON is a command that instr...
Page 26: ...mum value holding state Command 1 2 3 4 5 6 M A X B CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 35 MAXB ON command MAXB ON is a command that ins...
Page 27: ...state Command 1 2 3 4 5 6 7 M A X A B CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 38 MAXAB ON command MAXAB ON is a command that instructs maxi...
Page 28: ...um value holding state Command 1 2 3 4 5 6 M I N A CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 41 MINA ON command MINA ON is a command that inst...
Page 29: ...um value holding state Command 1 2 3 4 5 6 M I N B CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 44 MINB ON command MINB ON is a command that inst...
Page 30: ...ate Command 1 2 3 4 5 6 7 M I N A B CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 47 MINAB ON command MINAB ON is a command that instructs to hold...
Page 31: ...ation state Command 1 2 3 4 5 6 A M P A CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 50 AMPA ON command AMPA ON is a command that instructs to ho...
Page 32: ...ation state Command 1 2 3 4 5 6 A M P B CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 53 AMPB ON command AMPB ON is a command that instructs to ho...
Page 33: ...3 4 5 6 7 A M P A B CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 56 AMPAB ON command AMPAB ON is a command that instructs to hold the amplitude...
Page 34: ...nd 1 2 3 4 5 6 D E V A CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 59 DEVA ON command DEVA ON is a command that instructs to hold the deviation...
Page 35: ...nd 1 2 3 4 5 6 D E V B CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 62 DEVB ON command DEVB ON is a command that instructs to hold the deviation...
Page 36: ...A B CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 65 DEVAB ON command DEVAB ON is a command that instructs to hold the deviation of Ach and Bch fr...
Page 37: ...ation state Command 1 2 3 4 5 6 A V E A CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 68 AVEA ON command AVEA ON is a command that instructs to ho...
Page 38: ...ation state Command 1 2 3 4 5 6 A V E B CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 71 AVEB ON command AVEB ON is a command that instructs to ho...
Page 39: ...1 2 3 4 5 6 7 A V E A B CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 74 AVEAB ON command AVEAB ON is a command that instructs to hold the average...
Page 40: ...ation state Command 1 2 3 4 5 6 D Z R A CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 77 DZRA ON command DZRA ON is a command that instructs Ach t...
Page 41: ...ation state Command 1 2 3 4 5 6 D Z R B CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 80 DZRB ON command DZRB ON is a command that instructs Bch t...
Page 42: ...2 3 4 5 6 7 D Z R A B CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1 83 DZRAB ON command DZRAB ON is a command to instruct execution of Ach and Bch...
Page 43: ...with TRDT ON command is returned instead of the actual operation state Command 1 2 3 4 5 6 T R D T CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 1...
Page 44: ...te Specifiable pattern numbers are 1 to 8 The pattern number that operates is fixed until you cancel the instruction Command Specify pattern 1 1 2 3 4 5 6 7 8 P C H G 1 CR LF Command Specify pattern 8...
Page 45: ...is returned instead of the actual operation state Command 1 2 3 4 5 6 M L T A CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 2 2 MLTA ON command MLTA...
Page 46: ...on state Command 1 2 3 4 5 6 M L T B CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 2 5 MLTB ON command MLTB ON is a command that instructs execution...
Page 47: ...0 11 12 13 14 15 16 17 18 19 20 9 9 9 9 9 S 1 R U N CR LF Response Condition displaying 99999 overall result is OK and operation state is S4 finished 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20...
Page 48: ...th characters Display alarm condition ON OFF 15th to17th characters Display operation state RDY Waiting for operation start WIT Waiting for start condition RUN Running END Interval after section ends...
Page 49: ...T1A command 4 2 14 MT2B command MT2B command is a command to get the MultiHold parameters of section 2 of Bch MT2B returns displayed value section alarm condition and operation state Command 1 2 3 4 5...
Page 50: ...state Command 1 2 3 4 5 6 W V C A CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 2 18 WVCA ON command WVCA ON is a command that instructs to excution...
Page 51: ...state Command 1 2 3 4 5 6 W V C B CR LF Response No instruction 1 2 3 4 5 O F F CR LF Response With instruction 1 2 3 4 O N CR LF 4 2 21 WVCB ON command WVCB ON is a command that instructs to excution...
Page 52: ...onse Condition displaying 99999 overall result is NG and operation state is Finished 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 9 9 9 9 9 N G E N D CR LF 1st to 9th characters Display value Details...
Page 53: ...result CRLF Response example Instantaneous display value of Ach 9000 0 AL1 Result ON AL2 Result OFF AL3 Result NONE no allocation AL4 Result OFF 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21...
Page 54: ...e devices related to communication turned on Is the wiring correct Is the number of connected devices and connecting distance within specification range Whether the settings of communication condition...
Page 55: ...IM 0885 02 Number of pages 54 54 The contents of this instruction manual are subject to change without prior notice WATANABE ELECTRIC INDUSTRY CO LTD http www watanabe electric co jp en 6 16 19 JINGUM...