WATANABE A5000 Series Instruction Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Before Using the Product 

Thank you for purchasing the A5000 series. This manual should be passed on to 

the person who operates the product. Examine the product for damage caused by 

transportation or any other defects. If you find any damage or defects, contact the 

sales  agent  from  which  you  purchased  the  product  or  Watanabe

 

Electric

 

Industry Co., Ltd. 

1.1.Model Codes 

The model lineup of the A5000 series is shown below. Check that the model 

code and specifications of your product match those you specified when 

ordering.

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.Mounting the Product 

2.1.Dimensions for Cutting Panel 

Cut the panel for mounting according to the following dimensions. 

 

 

 

 

 

 

 

 

 

2.2.Mounting the Product to the Panel 

To mount the A5000 to the panel, remove its fittings and insert it through the 

hole in the front of the panel. From the back of the panel, fix the product to the 

panel with the fittings. 

 

 

 

 

 

 

 
 
 
 

Instruction Manual for A5000 Series

                   

 

 

 

                                                                                                          1/12 

UU-33554t 
2015.12 

MODEL A5000 SERIES

INSTRUCTION MANUAL

(1) Do not apply a voltage or current exceeding the maximum allowable 

value; otherwise, it may damage the equipment.

(2) Use a power voltage within the operation range; otherwise, it may result 

in a fire, electrical shock, or malfunction.

(3) The contents of this manual are subject to change without notice.

Although the contents of this manual have been prepared with extra 
care, if you have any questions, or find errors or missing information, 
contact the sales agent from which you purchased the product or 
Watanabe Electric Industry Co.,Ltd.

(4)

After reading this manual thoroughly, keep it in a convenient place for 
future reference.

(5)

Caution

!

The mark on a label shows the measurement tail range of the input 
specification of 8.1. clause.

(6)

01: DC voltage measuring unit

03: DC current measuring unit

02: DC voltage measuring unit

04: AC voltage measuring unit (average rms)

(range 11: ±99.99 mV)

(range 12: ±999.9 mV ; range 13: ±9.999 V)

(range 23: ±9.999 mA; range 24: ±99.99 mA)

(range 11: 99.99 mV; range 12: 999.9 mV)

05: AC voltage measuring unit  (average rms)

(range 14: 99.99 V; range 15: 600 V)

06: AC voltage measuring unit  (true rms)

(range 11: 99.99 mV; range 12: 999.9 mV)

07: AC voltage measuring unit (true rms)

(range 14: 99.99 V; range 15: 600 V)

08: AC current measuring unit (average rms)

 (range 23: 9.999 mA; range 24: 99.99 mA)

09: AC current measuring unit  (average rms)

 (range 23: 9.999 mA; range 24: 99.99 mA)

10: AC current measuring unit (true rms)

(range 26: 5 A)

11: AC current measuring unit (true rms)

12: Resistance measuring unit

13: Temperature measuring unit (TC)

14: Temperature measuring unit (RTD)

15: Frequency measuring unit

 (inputs: open collector, logic, and magnet)

16: Frequency measuring unit(input: 50 to 500 Vrms)

17: Strain gauze input unit (load cell)

(range 14:±99.99 V ; range 15: ±600 V)

18: Process signal measuring unit (4 to 20 mA or 1 to 5 V)

Input unit

(range 25: ±999.9 mA)

A 5 X X X - X X

(range 13: 9.999 V)

(range 13: 9.999 V)

 (range 25: 999.9 mA)

 (range 25: 999.9 mA)

(range 26: 5 A)

92

+0.8

-0

4

5

+

0

.6

-0

7

0

 m

m

 m

in

.

120 mm min.

WATANABE ELECTRIC INDUSTRY CO., LTD. 

0: None

Output unit

1: Comparison
2: Analog
3: RS-232C
4: RS-485
5: Comparison and analog
6: Comparison, analog, and RS-232C

Display unit

1: Single display
2: Multi display

Power unit

1: 100 to 240 V AC ±10%

7: Comparison, analog, and RS-485

A 5 X X X - X X

2: 9 to 60 V DC

Summary of Contents for A5000 Series

Page 1: ...reading this manual thoroughly keep it in a convenient place for future reference 5 Caution The mark on a label shows the measurement tail range of the input specification of 8 1 clause 6 01 DC volta...

Page 2: ...ential as COM Common for all external control terminals 1 2 3 Name Description 1 HI Positive input terminal 2 NC Do not connect this terminal 3 LO No Negative input terminal Name Description 1 12 Posi...

Page 3: ...Description 24 COM Common terminal for analog output 25 A OUT 26 No V OUT Current output terminal 4 to 20 mA Voltage output terminal 1 to 5 V 0 to 1 V and 0 to 10 V 20212223 Name Description 20 RXD RS...

Page 4: ...gment indicators HI 2 GO LO Indicates the result of judgment and turns on if the measured value HI judgment value Indicates the result of judgment and turns on if LO judgment value the measured value...

Page 5: ...tup 1000 S LO LO side judgment value setup 500 H HI HI side hysteresis setup 0 H LO LO side hysteresis setup 0 FSC Full scale Indication value setup 1 9999 9999 9999 9999 9999 9999 9999 9999 9999 9999...

Page 6: ...ide hysteresis setup 0 to 999 0 FSC Full scale indication value setup 9999 to 9999 FIN Full scale input value setup In the case of AC input please use it by setting by all means OFS Offset indication...

Page 7: ...dition data Indication 4 to 20mA 0 0 to 500 0 Output AOHI 5000 AOLO 0 Output Indication 20mA 5000 4mA 0 Multi display unit Single display unit 1 Press the Shift Increment and Enter keys together durin...

Page 8: ...or details on the RS 485 function see the separate manual on communication functions 7 4 RS 232C Interface Function The A5000 series can be equipped with an RS 232C interface when the meter is provide...

Page 9: ...le ended type 15 Operating system conversion Maximum sampling rate 12 5 times per second Frequency range 40 Hz to 1 kHz Response speed About 1 second Dead zone 0 to 99 digits 600V 10mV 600V 0 3 of FS...

Page 10: ...version Maximum sampling rate 12 5 times per second PT100 JPt100 100 0 to 199 9 148 0 to 391 8 F 100 to 600 148 to 1112 F 1 1 F 0 3 of FS JPt100 PT100 Current through RTD About 1 mA External resistanc...

Page 11: ...ple 0 to 1V 0 to 10V 1 to 5V 4 to 20mA 10k or more 10k or more 10k or more 550 or less 0 5 of FS 50mVp p 25mVp p Note The ripple ratings for the 4 20 mA output are when the load resistance of 250 and...

Page 12: ...value setup 9999 DATA Data length setup 7 AOHI Analog output HI indication setup 9999 P BIT Parity bit setup E AOLO Analog output LO indication setup 0 S BIT Stop bit setup 2 DEP Decimal point positi...

Page 13: ...ng Transmission rate Number of start bits Data length Error detection Block check character BCC checksum Number of stop bits Character code Transmission control procedure Signal name used TXD RXD SG N...

Page 14: ...r to ON Note The figure below identifies the position of the selector socket for switching between the ON and OFF positions Parts mounted side of WA5000 output unit Communication connector Side mounte...

Page 15: ...5 0 0 0 CR LF 12 reading w decimal point 9 8 0 0 CR LF 12 overrange reading w o decimal point 9 8 0 0 CR LF 12 overrange reading w decimal point All responses are the fixed length of 12 characters Co...

Page 16: ...Y E S CR LF 5 Clears the peak valley hold values Peak hold remote control cancellation E P M CR LF 3 Y E S CR LF 5 Comparison output remote control R L Y CR LF 3 R L Y O F F CR LF 7 response Response...

Page 17: ...mes M A V O N 1 6 CR LF Response with the status of the moving average calculation frequency being 16 times Moving average calculation M A V 4 CR LF 5 Y E S CR LF 3 frequency setting Sets the moving a...

Page 18: ...ay function being set to OFF P O N 1 CR LF 5 Response with the status of the power on delay function being set to 1 sec P O N 3 0 CR LF 6 Response with the status of the power on delay function being...

Page 19: ...2 CR LF 6 Y E S CR LF 5 correction data items Sets the number of linearization correction data items to 02 L N O 1 6 CR LF 6 Y E S CR LF 5 Sets the number of linearization correction data items to 16...

Page 20: ...correctly and a transition is made to span calibration Note Check the applied input signal level or span reading and set the calibration data again Response when an input signal that is outside the ze...

Reviews: