(1)The application of voltage or current exceeding its maximum 

allowable value to the input terminals may result in instrument 

damage. 

(2)The supply of power out of its allowable range may cause fire, 

electric shock or instrument failure. 

(3)The content of this manual may subject to change without prior 

notice for product improvement. 

(4)This manual is carefully prepared. However, if any question  

arises, or any mistake, omission or suggestion is found in the 

content of this manual, contact your nearest our sales agent. 

 

1.Before operation

 

 

1-1 Checking Model No. 

    Each of AP-244A Model Nos. is configured as shown in the following, 

check that the Model No. ordered matches that delivered. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.2 Checking accessories 
   The following accessories will come with the AP-244A. 
     Lower 10-pin connector・・・・・1 pc. 
     Instruction manual・・・・・・・1 copy 
     Upper 26-pin connector・・・・・1 pc. 
     (Only with BCD output) 
   If you have any query, please contact our sales agent or Watanabe 

directly. 

1.3 Mounting 
   1.3.1 Panel cutout dimensions 

Make the panel cutout for mounting the AP-244A according to the 
following Fig. 

 

 

 

 

 

 

 

 

 

 

 

 

1.3.2 Mounting the AP-244A 

When mounting the AP-244A in the panel, push the meter in the panel 

from the panel front while pressing down the snaps located at the 

sides of the case. 

 

1.4 Terminal connection diagram 

 

 

 

 

 

 

 

 

 

 

*Do not gradually apply the power supply voltage to the meter but 
from 0V quickly to the rated voltage. (If the voltage is gradually 
increased, the meter may not start.) 

2. Various functions 

 

2.1 Setting the position of decimal point 

The position of the decimal point of this meter can be externally 
controlled from the lower connector terminals. Short the terminal 
corresponding to the digit to be lit with the COM terminal. 

 

2.2 Start/hold function 

 

 The start/hold function is used to control display hold 

(measurement stop) and start (measurement start) from the external 
control terminals.  

  Measurement is held with the START/HOLD terminal shorted with the 

COM terminal (or level 0) or started with the START/HOLD terminal 
opened from the COM terminal (or level 1). 

  In addition, a positive pulse within one-sampling time exceeding 

1 ms enables one-shot measurement. 

  The function of the START/HOLD terminal wired on the upper side 

when the BCD output is optionally provided is the same as that 
described above. 

  However in this case, the control line is isolated from the input 

signal line. 

 

 

 

 

 

 

 

 

 

 

 

 

2.3 BCD output 

This  meter  can  provide  the  parallel  BCD  output  as  option.  In 
addition, for the BCD output of this meter, the input circuit is 
isolated from the power circuit. 

 2.3.1 Terminal connection diagram 

 

 

 

 

 

 

 

 

2.3.2 Output status[( );For TTL] 
  Measured data; 
    Negative logic (Positive logic) 
  Polarity signal; 
    Transistor turned on at plus (Logic 1) 
  OVER signal; 
    Transistor turned on at OVER (Logic 1) 
  Printing command output (PC); 
    Transistor  turned  on  (Logic  1)  for  about  10  ms  every  time 

measurement is complete. 

  Output capacity; 
    Max. voltage 30V 
    Max. current 15 mA (Fanout 2) 

INSTRUCTION MANUAL 

DIGITAL PANEL METER 
MODEL AP-244A SERIES 

Caution 

WATANABE ELECTRIC INDUSTRY CO., LTD.