Enter/Exit Programming Mode
Label ID
58
Wasp WDI7500/WWS750
Individually Set Label ID
This feature configures a Label ID individually for a single symbology. To
set, first define whether you want it as a prefix or suffix by scanning a label
below. Then turn to
Symbologies, starting on page 59
to select the symbology you want to set,
followed by up to 3 characters from the ASCII Chart at the back of this man-
ual. See "
Label ID: Set Individually Per Symbology" on page 248
for detailed
instructions on setting this feature.
Label ID Control
This option controls whether a Label ID is disabled, or sent as a prefix or
suffix for a given symbology type.
DEFAULT
$CIDCO00(CR)
Label ID Transmission = Disable
$CIDCO01(CR)
Label ID Transmission = Enable as Prefix
$CIDCO02(CR)
Label ID Transmission = Enable as Suffix