32
Installation manual
7.8
Data label
When the machine is to be converted to another gas type, the data label at the front panel of the machine must be
updated in order for the data to be correct.
Select the Sticker C (Rating Plate of Propane Gas) or Sticker D (Rating Plate of Butane Gas) in the accessory bag
covering the original data label as shown below.
Note the correct country code and gas type.
For safety reasons use only genuine spare parts
AT BE, CY, CZ, DE, DK, EE, FR, GB, HR, HU, IT, LT, NL, NO,
RO, SE, SI, SK: I3B/P (30)
STICKER D
Burner Pressure: 27.4 mbar Gas Pressure: 29mbar
Gas Type: G30 Injector: Ø1.21mm Nominal Heat Input: 5.7kW(Hi)
BE, CH, CZ, ES, FR, GB, GR, HR, IE, IT, LT, NL, PL, PT, SI,
SK, TR: I3P (37)
For safety reasons use only genuine spare parts
STICKER C
Burner Pressure: 36mbar Gas Pressure: 37mbar
Gas Type: G31 Injector: Ø1.21mm Nominal Heat Input: 5.7kW(Hi)
For safety reasons use only genuine spare parts
HU: I2H (25)
DE, PL, RO: I2E (20)
Burner Pressure: 7.7mbar Gas Pressure: 20mbar/25m
bar(HU)
Gas Type: G20 Injector: Ø2.26mm Nominal Heat Input: 5.7kW(Hi)
AT, CH, CY, CZ, DK, EE, ES, FI, FR, GB, GR, HR, IE, I T, LU, LV, LT,
NO, PT, RO, SE, SK, SI, TR: I2H (20)
,
Ser.No.
Electrolux Professional S.p.A.
Viale Treviso, 15 - 33170 Pordenone
Italy
9031000130
Rated Input: 750W 15A
Capacity: 12kg
PIN. NO.: 1336DL005
1336/20
Pro.No.
988690062
220-240V 50Hz
MODEL:
SD-12G
~
00
IPX4
Made in China
Gas Dryer
fig.W01632B