6HUYLFH0RGH
6:2
STATISTICS (NON-RESETTABLE):
000 - Cold program counter. Range: 0000 to F999, (A=10, ... F=15 e.g. “B101” = 11,101)
001 - Warm program counter. Range: 0000 to F999
002 - Hot program counter. Range: 0000 to F999
003 - Delicate program counter. Range: 0000 to F999
004 - Rinse and Spin program counter. Range 0000 to F999
005 - Heavy soil option (only) counter. Range: 0000 to F999
006 - Extra rinse option (only) counter. Range: 0000 to F999
007 - Heavy Soil & Extra Rinse counter both options selected Range: 0000 to F999
008 - Total program counter i.e. 00+01+02+03+04 . Range from 0000 to F999
&RLQWRWDOL]HU¿UVWGLJLWVIURPWR
&RLQWRWDOL]HUODVWGLJLWVIURP
*011 - Newest error and time stamp. “011”>E ##>yyyy>mm.dd>hh.mm>(reg 8)>”010”
*012 - 2nd latest error and time stamp.
*013 - 3rd latest error and time stamp.
*014 - Oldest error and time stamp. “014”>E ##>yyyy>mm.dd>hh.mm>(reg 8)>”010”
015 - Coin box access 1 time stamp: (Most recent access)
016 - Coin box access 2 time stamp:
017 - Coin box access 3 time stamp:
018 - Coin box access 4 time stamp: (Oldest access).
*019 - Firmware version.
Statistics (000-010):
Program and option counts are updated when the cycle ends. When in coin
mode (decimal in price), registers 009-010 shows the value of the amount collected. When in no-
decimal mode (token), 009-010 shows the number of coins collected. When both program options
have been selected for a program, register 007 is incremented but not registers 005 and 006.
(UURU&RGHV
Selecting an error register displays the error code. Each successive press
of the START button (>) advances the display: Year > Month.Day > Hour.Minutes > Total Program
Count > Register Exit. As new errors occur, they are saved in register 011 and the older records
shift up by one register location. The original contents of register 014 are discarded.
&RLQ%R[$FFHVV
Each successive press of the START button (>) advances the display:
Year > Month.Day> Hour.Minutes> Register Exit. With each opening of the coin box, the register
time stamps are saved in register 015 and the older records shift up by one register location. The
original contents of register 018 are discarded.
Wash Program Parameters:
020 - Low water level (prewash & wash): range 5-32 (Approximate volume in liters, default = 07”).
021 - High water level (rinse): range 5-32 (Approximate volume in liters, default = 10”).
022 - Delete rinse 2: range “00” or “01”, default=“01” (rinse 2 deleted).
023 - Delete prewash: range “00” or “01”, default=“01” (prewash deleted).
024 - Default program selection:
00= No cycle selected (display “----“). Enables RINSE&SPIN program selection.
01= COLD cycle is default (This is the factory default)
02= WARM cycle is default
03= HOT cycle is default
04= DELICATE cycle is default.
Summary of Contents for Encore WHLFP715M
Page 1: ...W A S H E R O P E R A T I N G M A N U A L MODEL NO WHLFP715M DOC NO 098014 EDITION 09 2018 ...
Page 2: ...Intentionally blank ...
Page 4: ...Intentionally blank ...
Page 6: ...SAFETY AND WARNINGS SIGNS WARNING LABEL FOR POWER CABLE FIRE HAZARD LABEL ADJACENT TO DOOR ...
Page 10: ...Intentionally blank ...
Page 15: ...Intentionally blank ...
Page 17: ...Intentionally blank ...