94-0601-C
16
RS24 Electrical Interface
The RS24 sensor uses a connector interface. There are two connectors - 3 way for power and 6 way for Ethernet.
Users can assemble their own mating connectors using suitable Amphenol CO16 plugs or purchase pre-assembled cables from Wärtsilä Guidance Marine Ltd.
Main Power 86-264VAC 50-60Hz
Connector: Amphenol C016 20C003 200 12
3way + Power Earth (PE)
Pin 1
Live
Pin 2
Neutral
Pin 3
N/A
PE
Earth
Ethernet Comms
Connector: Amphenol C016 30G006 200 12
6way + Power Earth (PE)
Connector
Function
CAT5 Cable Colour
Pin 1
RX+
Orange/White
Pin 2
RX-
Orange
Pin 3
N/C
Pin 4
N/C
Pin 5
TX-
Green
Pin 6
TX+
Green/White
PE
Earth
Braid
Wärtsilä Guidance Marine mating cable assy:
33-0564-
xx
M where
xx
= length of cable in meters
Wärtsilä Guidance Marine mating cable assy:
33-0562-
xx
M where
xx
= length of cable in meters (
should not exceed 90 metres in
length)
29
[1,142]
31
[1,220]
38
[1,496]
ø3,6
[,142]
29
[1,142]
31
[1,220]
38
[1,496]
ø3,6
[,142]
Installing the Sensor Hardware and Software
2
2.5