3.2
Wärtsilä 8V31DF
ME
AUX
AUX
DE
DE
Wärtsilä 8V31DF
Diesel
mode
Gas
mode
Diesel
mode
Gas
mode
Diesel
mode
Gas
mode
Diesel
mode
Gas
mode
Diesel
mode
Gas
mode
750
750
720
750
720
rpm
Engine speed
550
550
530
550
530
kW
Cylinder output
Variable
Constant
Constant
Constant
Constant
Speed mode
4400
4400
4240
4400
4240
kW
Engine output
2.71
2.71
2.72
2.71
2.72
MPa
Mean effective pressure
Tier 2
Tier 3
Tier 2
Tier 3
Tier 2
Tier 3
Tier 2
Tier 3
Tier 2
Tier 3
IMO compliance
Combustion air system (Note 1)
8.4
6.6
8.4
6.6
8.1
6.4
8.4
6.6
8.1
6.4
kg/s
Flow at 100% load
45
45
45
45
45
°C
Temperature at turbocharger in-
take, max.
60
60
60
60
60
60
60
60
60
60
°C
Temperature after air cooler (TE
601)
Exhaust gas system (Note 2)
8.7
7.4
8.7
7.4
8.1
7.1
8.7
7.4
8.1
7.1
kg/s
Flow at 100% load
7.4
6.1
7.4
6.1
6.9
5.9
7.4
6.1
6.9
5.9
kg/s
Flow at 85% load
6.6
5.5
6.9
5.4
6.4
5.2
6.9
5.4
6.4
5.2
kg/s
Flow at 75% load
5.0
3.8
4.9
3.8
4.6
3.7
4.9
3.8
4.6
3.7
kg/s
Flow at 50% load
270
300
270
300
270
300
270
300
270
300
°C
Temperature after turbocharger
at 100% load (TE 517)
260
320
270
350
270
350
270
350
270
350
°C
Temperature after turbocharger
at 85% load (TE 517)
270
310
260
350
260
350
260
350
260
350
°C
Temperature after turbocharger
at 75% load (TE 517)
270
330
280
370
280
370
280
370
280
370
°C
Temperature after turbocharger
at 50% load (TE 517)
7
7
7
7
7
kPa
Backpressure, max.
697
657
697
657
671
647
697
657
671
647
mm
Calculated exhaust diameter for
35 m/s
Heat balance at 100% load (Note 3)
424
360
424
360
408
344
424
360
408
344
kW
Jacket water, HT-circuit
768
504
768
504
680
472
768
504
680
472
kW
Charge air, HT-circuit
1296
1064
1304
1072
1208
1024
1304
1072
1208
1024
kW
Charge air, LT-circuit
488
408
488
408
472
392
488
408
472
392
kW
Lubricating oil, LT-circuit
120
120
120
120
120
120
120
120
120
120
kW
Radiation
Fuel consumption (Note 4)
(Note 5)
-
7280
-
7280
-
7250
-
7280
-
7250
kJ/kWh
Total energy consumption at
100% load
-
7230
-
7350
-
7300
-
7350
-
7300
kJ/kWh
Total energy consumption at 85%
load
-
7250
-
7500
-
7430
-
7500
-
7430
kJ/kWh
Total energy consumption at 75%
load
-
7330
-
7820
-
7790
-
7820
-
7790
kJ/kWh
Total energy consumption at 50%
load
-
7128
-
7128
-
7097
-
7128
-
7097
kJ/kWh
Fuel gas consumption at 100%
load
DBAE248994
3-3
3. Technical Data
Wärtsilä 31DF Product Guide
Summary of Contents for ?31DF Series
Page 1: ...PRODUCT GUIDE W rtsil 31DF...
Page 4: ...This page intentionally left blank...
Page 8: ...This page intentionally left blank...
Page 14: ...This page intentionally left blank...
Page 74: ...This page intentionally left blank...
Page 84: ...This page intentionally left blank...
Page 134: ...This page intentionally left blank...
Page 150: ...This page intentionally left blank...
Page 154: ...This page intentionally left blank...
Page 164: ...This page intentionally left blank...
Page 182: ...This page intentionally left blank...
Page 188: ...This page intentionally left blank...
Page 196: ...This page intentionally left blank...
Page 204: ...This page intentionally left blank...
Page 210: ...This page intentionally left blank...
Page 212: ...This page intentionally left blank...
Page 215: ......