background image

sandpiperpump.com

Model HP10  

Metallic - High Pressure 
Design Level 1

Certified Quality

Warren Rupp, Inc.

A Unit of IDEX Corporation

800 N. Main St.,  

Mansfield, Ohio 44902 USA  

 

Telephone 419.524.8388

Fax 419.522.7867

SANDPIPERPUMP.COM

© Copyright 2017 Warren Rupp, Inc.

All rights reserved

ISO 9001 Certified 

I

SO 14001 Certified

1: PUMP

 SPECS

2: INST

AL

 & OP

3: EXP

 VIEW

4: 

AIR END

5: WET END

6: OPTIONAL

7: W

ARRANTY

 

SERVICE & OPERATING MANUAL

Original Instructions

Summary of Contents for SANDPIPER HP10

Page 1: ...oration 800 N Main St Mansfield Ohio 44902 USA Telephone 419 524 8388 Fax 419 522 7867 SANDPIPERPUMP COM Copyright 2017 Warren Rupp Inc All rights reserved ISO 9001 Certified ISO 14001 Certified 1 PUM...

Page 2: ...kg WARNING The use of non OEM replacement parts will void or negate agency certifications including CE ATEX CSA 3A and EC1935 compliance Food Contact Materials Warren Rupp Inc cannot ensure nor warra...

Page 3: ...X 20 C to 50 C 20 C to 100 C T5 T100 X Ambient Temperature Range C Process Temperature Range C 20 C to 60 C 20 C to 150 C 1 Per CSA standards ANSI LC6 2018 US Canadian Technical Letter R14 G Series N...

Page 4: ...Composite Repair Parts Drawing Composite Repair Parts List Material Codes SECTION 4 AIR END 11 Air Distribution Valve Assembly Air Valve with Stroke Indicator Assembly Pilot Valve Assembly Intermediat...

Page 5: ...ne Neoprene T Neoprene PTFE PTFE Your Serial fill in from pump nameplate ______________________________________ Pump Pump Check Design Wetted Diaphragm Check Valve Non Wetted Porting Pump Pump Kit Bra...

Page 6: ...rpose oil resistant Shows good solvent oil water and hydraulic fluid resistance Should not be used with highly polar solvents like acetone and MEK ozone chlorinated hydrocarbons and nitro hydrocarbons...

Page 7: ...ied drawing can be requested if physical dimensions are needed Dimensional Drawings 1 97 50 12 99 330 10 98 279 DISCHARGE OUTLET 1 FNPT 1 FBSPT SUCTION INLET 1 FNPT 1 FBSPT 7 93 202 4 45 113 5 36 136...

Page 8: ...side check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanicall...

Page 9: ...p operating Water in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off valve After the pump primes the air valve ca...

Page 10: ...a point of use air drier Clogged manifolds Clean manifolds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is de...

Page 11: ...391 360 WET END KIT BUNA Buna Diaphragms Buna Check Balls Buna O Rings 476 391 365 WET END KIT NEOPRENE Neoprene Diaphragms Neoprene Check Balls Neoprene O Rings 476 391 635 Wet End Kit PTFE PTFE Diap...

Page 12: ...el HP10 High Pressure sandpiperpump com TORQUE SETTINGS A B D AIR SIDE EXPLODED ASSEMBLY 34 476 392 000 AIR END KIT Air Side Diaphragm Air Hoses Seals and O rings Composite Repair Parts Drawing Servic...

Page 13: ...204 Gasket Air Valve 1 32 40 225 Bracket Foot 2 Composite Repair Parts List ATEX Compliant LEGEND Items contained in 476 392 XXX Air End Kits Items contained in 476 391 XXX Wet End Kits Note Kits con...

Page 14: ...emoved together with air chamber diaphragm and locking plate etc Assembly is reverse of removal after first fitting seal guide supplied in air side kit SA10459 into end of diaphragm shaft as shown abo...

Page 15: ...tions When looking from the air valve side of the pump air hoses items 19 20 are connected as shown Inner chamber LH 22 connects to LH spacer chamber 21 and inner chamber RH 10 connects to RH spacer c...

Page 16: ...functioning of all pneumatically actuated valve systems Check the diaphragm shaft for excessive wear as this will result in premature seal failure Replace as required Lubricate all components and re a...

Page 17: ...N809 2012 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that...

Page 18: ...es ST Series Conductive plastic pump models with integral muffler S Series PB Series Tranquilizer surge suppressors Hazardous Location Applied I M1 Ex h I Ma II 1 G Ex h IIC T5 225 C T2 Ga II 1 D Ex h...