TH115 A/F/AF
1/2
The TH115 programmable thermostat has three temperature control
modes:
1
Place the switch to Off to cut power to the heater when not in use
(e.g., in the summer). This will not affect the time and temperature
settings.
2
The thermostat displays the percentage of heating time required to
maintain the desired temperature. For example, is displayed when
heating is activated 40 percent of the time.
1) Press the Hour button to set the hour.
2) Press the Min button to set the minutes.
3) Press the Day button to set the day.
4) Press the Mode/Ret button to exit.
The display illuminates for 12 seconds when the backlight button is
pressed.
When either of the
buttons is pressed, the display also illuminates
for 12 seconds. The setpoint temperature appears for 5 seconds,
then the actual (measured) temperature is displayed.
Setpoint Temperature
The thermostat normally displays the actual (measured) temperature.
To view the setpoint, press one of the
buttons once. The setpoint
will appear for the next 5 seconds.
To change the setpoint, press one of the
buttons until the desired
temperature is displayed. To scroll faster, press and hold the button.
Preset Temperatures
The thermostat has 3 preset temperatures:
• Comfort temperature
• Economy temperature
• Vacation temperature
To use a preset temperature, press the corresponding button. The
corresponding icon , or will be displayed.
The following table shows the intended use and the default setting of
each of the preset temperatures.
T
o store a preset temperature:
1) Set the desired temperature using the
buttons.
2) Press and hold the corresponding button until the corresponding
icon is displayed.
Floor Temperature Limits (AF mode only)
NOTE: To avoid damaging your floor, follow your floor supplier’s
recommendations regarding floor temperature limits.
The minimum and maximum floor temperature limits are 5 °C and
28 °C by default. To modify these limits, proceed as follows:
1) Switch the thermostat to Off.
2) Press and hold the button.
3) Switch the thermostat back to On.
4) Release the button when the minimum temperature
limit (FL:LO) appears.
5) Set the minimum temperature limit using the
buttons.
6) Press the button to display the maximum
temperature limit (FL:HI).
7) Set the maximum temperature limit using the
buttons.
8) Press Mode/Ret to exit.
Description
A mode:
controls the ambient air temperature
F mode:
controls the floor temperature using an external
temperature sensor
AF mode:
controls the ambient air temperature
maintains the floor temperature within desired limits
using an external temperature sensor
Display
% of heating time
1 to 24% 25 to 49% 50 to 74% 75 to 99%
100%
Clock and Day Setting
Backlight
On/Off switch
1
Day and time
settings
Temperature
adjustment buttons
Program button
Mode selection /
program exit
Temperature display
Mode display
Period display
Temperature
preset buttons
Time and day display
Percentage of
heating time
2
Backlight button
Program clear
button
Preset temperature
indicator
Appears when the
setpoint is displayed
Temperature control
mode indicator
Keep the thermostat's air vents clean and unobstructed at all times.
Keep the thermostat's air vents clean and unobstructed at all times.
Temperature Adjustment
Icon
Intended use
A/AF modes
F mode
Comfort
(when at home)
21 °C
24 °C
Economy
(when asleep or away from
home)
17 °C
16 °C
Vacation
(during prolonged absence)
10 °C
10 °C
TH115 A/F/AF
User Guide
Programmable Thermostat