background image

16 March 2023

 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.

 

1

 

Gas Type Conversion NG/LPG

 

NG to LPG

 

 

1.

 

Jets needs to be replaced.

 

2.

 

Jumper needs to be removed from the control box.

 

3.

 

Pressures needs to be adjusted.

 

4.

 

Pilot needs to replaced, make sure air

-

intake is opened.

 

 

 

LPG to NG

 

 

1.

 

Jets needs to be drilled out

 

2.

 

Jumper needs to be added to the control box.

 

3.

 

Pressures needs to be adjusted.

 

4.

 

Pilot needs to replaced, make sure air

-

intake is closed.

 

 

 

 

 

 

 

 

 

 

NG to LPG

 

 

1.

 

Jets needs to be replaced.

 

2.

 

Remove NG regulator

 

3.

 

Pressures needs to be adjusted.

 

4.

 

Pilot needs to be adjusted and air

-

intake on it opened.

 

 

 

LPG to NG

 

 

1.

 

Jets needs to be drilled out

 

2.

 

NG regulator to be added

 

3.

 

Pressures needs to be adjusted.

 

4.

 

Pilot needs to be adjusted and air

-

intake closed

 

1.1 TYPES OF CONVERSIONS

 

1.1.1 EG SERIES ELECTRONIC 

 

1.1.2 SG SERIES MANUAL

 

Summary of Contents for SG-EG 600

Page 1: ...LPG to NG 1 Jets needs to be drilled out 2 Jumper needs to be added to the control box 3 Pressures needs to be adjusted 4 Pilot needs to replaced make sure air intake is closed NG to LPG 1 Jets needs...

Page 2: ...ffect Effect Effect Supply Pipe Size dia min 3 8 3 8 1 2 1 2 3 8 Natural Gas Nominal Pressure kPa 1 5 kPa 1 5 kPa 1 5 kPa 1 5 kPa 1 5kPa Nominal Injector Size mm 2 X 1 8mm 2 X 2mm 2 X 2 2mm 2 X 2 4mm...

Page 3: ...over Use a spanner to unscrew the NG jet head only and replace the jet head with the supplied new LPG jet heads Refer to the table in section 1 2 for the number of jets to be replaced 2 1 1 JET ADJUST...

Page 4: ...ove test equipment and secure test nipple screw Check valve burner for correct operation check for gas leaks Adjustment of High Low Settings Must be Carried out by a Certified Gas Fitter Only Gas test...

Page 5: ...f a few times to check ignition When you are satisfied that the Appliance is working correctly fit the Front Panel Assembly back to the Gas Burner All Burner Aerations are Factory Preset and cannot be...

Page 6: ...trodes on both sides Replace the Base screw and check for leaks Pilot in Assembled State Correct Operation of Pilot 3 2 1 3 1 PILOT ADJUSTMENTS 3 1 2 PILOT FLAME ADJUSTMENT 3 1 3 PILOT AIR ADJUSTMENT...

Page 7: ...or take out best tool to use is tweezers Take care not to lose the jumper as it is small and can be hard to recover if lost Jumper 5 1 NG REGULATOR FOR SG MANUAL FIRES ONLY All manual NG gas burners...