21

warmhaus.com

2.6. RECOMMENDATIONS FOR 

ECONOMICAL USE OF

Your is adjusted at ECO mode for economic use, we 
recommend not to change it

Correct Capacity Selection

Heat loss calculation of the boiler location should be 
made correctly and boiler capacity should be selected 
accordingly. Devices not having adequate capacity shall 
give late responses to heating requests, devices with 
higher capacity may cause discomfort and more fuel 
consumption as they turn ON and OFF more frequently. 
Therefore, boiler capacities should be selected according 
to the place used.

Insulation

Insulation of your building is the most important item 
reducing the heat loss and gas consumption. However, as 
your has the highest thickness insulation of its class, heat 
loss is minimized.

Radiators

Ensure balancing the rest pump head of the appliance 
by making reduction adjustments from radiator 
valves. Placing furnitures in front of radiators prevents 
air circulation and causes discomfort and more fuel 
consumption. Reducing radiator valves of rooms not used 
for a long period or if thermostatic radiator valve is used, 
bringing to the lowest position then, closing room doors 
will provide saving.

Domestic Hot Water

Always adjust the domestic hot water temperature as 
(38~42 °C) for a considerable power saving. In addition, 
high domestic hot water temperatures cause strong 
calcification and that negatively affects operation of the 
device (for instance, longer heating periods, less flow 
rate).

Thermostatic Radiator Valves 

You can both acquire savings and comfort by balancing 
the heat distribution among the house by using 
Thermostatic Radiator Valves.

Room Thermostats 

Your boiler will operate more economically as you will 
have the chance to adjust requested room temperature 
according to comfort via room thermostats. Thus, you can 
adjust temperature of your room as you wish, and also 
you can acquire approximately 6% power saving with 
every degree of temperature decrease.

Ventilation

Do not leave windows slightly open for ventilating room/

rooms. In such case, continuous heat loss will occur and 
not having any certain improvement in the room air.

Fully opening windows for a short period provides a 
better result. Bring thermostatic radiator valves to lowest 
position when ventilating rooms.

Cleaning And Maintenance

Attention:

 to preserve the boiler’s integrity and keep the 

safety features, performance and reliability, you must at 
least execute maintenance operations on a yearly basis 
in compliance with national, regional, or local standards 
in force. 

We recommend a yearly cleaning and maintenance 
contract with an authorised local firm.

2.7. ISSUES REQUIRED TO BE 

TAKEN INTO CONSIDERATION FOR 

WARRANTY CONDITIONS

Under below given conditions, warrnaty of the product 
will be void :

1. 

Damages and failures occurring in devices which are 
not commissioned Authorised Services,

2.

  Damages and failures arising from use of the product 

contrary to items given in User’s Manual and using out 
of its intended purpose.

3.

 Damages and failures arising from wrong type 

selection,

4.

 Damages and failures arising from maintenance and 

repairs performed by persons other than Authorised 
Services,

5.

  Damages and failures occurring due to transportation, 

unloading, loading, storing, external physical (Crushing, 
scratches, fractures) and chemical factors following 
delivery of the Product,

6.

  Damages and failures arising from fire and lightning,

7.

  Damages and failures arising from false fuel use and 

fuel characteristics,

8.

  Low or excessive voltage, unearthed socket usage;

9.

 Damages and failures arising from faulty electricity 

installations,

10.

Damages and failures arising from failing to perform 
timely annual maintenance and cleaning,

11.

Damages and failures arising from frost/icing or 

occurring due to using in the outdoor places (open 
balcony, etc.).

12.

Altering the Registry Label and Warranty Certificate,

13.

Damages and failures arising from using water out of 

the water values defined in device user’s guide,

Summary of Contents for MINERWA 25 COMBI-IE

Page 1: ...MINERWA 25 31 COMBI IE MINERWA 25 SYSTEM IE CONDENSING BOILER USER MANUAL...

Page 2: ...2 warmhaus com MinerWa 25 31 Combi IE MinerWa 25 System IE...

Page 3: ...OFF STAND BY AND SUMMER WINTER MODES 10 2 1 3 ON OFF STAND BY POSITIONS 10 2 1 4 OPERATION IN WINTER MODE 11 2 1 5 OPERATION IN SUMMER MODE 11 2 1 6 SHUTTING OFF THE BOILER 12 2 2 USE WITH ROOM THERM...

Page 4: ...iler should be performed by our authorised Warmhaus service Project design and application for LPG use should be performed by the company supplying the tank in accordance with local and legal rules 1...

Page 5: ...on installation of gas fired heating devices www warmhaus com Manufacturer WARMHAUS Is tma ve So utma Sistemleri Tic A Bursa I ktepe OSB Mah Park Cad No 10 16140 Nil fer Bursa T rkiye WARMHAUS Warmha...

Page 6: ...G20 DE II 2ELL3B P Natural Gas 20 mbar G20 DE I 2L Natural Gas 25 mbar G25 NL I 2E Natural Gas 25 mbar G25 BE FR I 2ELL Natural Gas 20 mbar G25 DE II 2L3P Natural Gas 25 mbar G25 NL II 2L3B P Natural...

Page 7: ...0 mbar G30 AT CH SK II 2E3B P Buthane Gas 50 mbar G30 DE II 2L3B P Buthane Gas 30 mbar G30 NL II 2ELL3B P Buthane Gas 50 mbar G30 DE I 3P Propane LPG 37 mbar G31 BE CH CZ ES FR GB GR HR IE IT LT NL PL...

Page 8: ...ff the gas supply at the gas meter or an appropriate emergency control valve Immediately evacuate the place Call the National Gas Emergency Service 0800111999 or in Ireland 1850 20 50 50 Do not make a...

Page 9: ...es should be replaced by the Authorised Service Do not expose the boiler to direct vapour those may arise from cooking places Safety In your own interest and that of safety it is the law that this boi...

Page 10: ...3 16 18 9 8 14 10 15 12 11 17 RESET It is used for resetting the failure if temporary re starting the boiler MODE Used for Winter Summer OFF mode adjustment Operating modes and related notifications O...

Page 11: ...en light is turned off When boiler is started flame modulation symbol is seen at the middle section of the screen At that position you can increase and decrease the temperature with CH temperature adj...

Page 12: ...om thermostats compatible with Warmhaus boilers Do not remove device components during operation Do not place the boiler in a position allowing direct sunlight exposure or near heat sources Manufactur...

Page 13: ...sing RESET and for circle time Air will be displayed on the screen Boiler will start the Deareation function During this function pump and 3 way valve are activated deactivated in order to have deaera...

Page 14: ...omestic hot water temperature sensor faulty Boiler does not work in DHW mode but still operational in Central heating mode E04 error code flashing on the screen Domestic heating water temperature sens...

Page 15: ...FLUE temperature sensor faulty 1 Reset Restart boiler 2 Call for authorised service E 15 Fan failure feedback supply Boiler does not work E15 error code flashing on the screen Fan harness 1 Reset Res...

Page 16: ...provider 2 Error will remove if supply voltage 170 VAC 5 3 If this failure is observed during calibration calibration can not be complete unless supply voltage 188 VAC 5 E 40 Wrong network frequency...

Page 17: ...thorised service at first 2 Check RETURN and FLOW sensor on position E 74 Second CH temperature Probe faulty Boiler does not work E74 error code flashing on the screen FLOW and LIMIT Sensor double NTC...

Page 18: ...ng on the screen Strong flue blockage Combustion problem Wrong flue Gas inlet pressure Aging or rust on the electrode Recirculation of exhaust gas into fresh air Electrode position Combustion calibrat...

Page 19: ...air Blockage in flue or wrong flue Electrode position Cabling disconnections Combustion calibration Electronic board Gas valve failure 1 Call for authorised service E 92 Air compensation active Boiler...

Page 20: ...ctrode Electrode position Combustion calibration 1 Call for authorised service E 96 Flue or air suction way blockage Boiler does not work E96 error code flashing on the screen Blockage in flue Blockag...

Page 21: ...oximately 6 power saving with every degree of temperature decrease Ventilation Do not leave windows slightly open for ventilating room rooms In such case continuous heat loss will occur and not having...

Page 22: ...22 warmhaus com...

Page 23: ...nt have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet All goods are sold...

Page 24: ...and 24 hour emergency line immediately or 1850 20 50 50 Don t assume somebody else has reported the smell Carbon monoxide information For further Information on carbon monoxide call 1850 79 79 79 The...

Reviews: