890557_d•en•01.07.2014
We reserve the right to carry out improvements
53
7.2.3.7 Position COL
The “Position COLD” value specifies the position at which the sun shading
product is to be raised. The setting range is 0-100%; a value of 0% corre-
sponds to the upper limit position and a value of 100% to the lower limit posi-
tion.
Turn the touch wheel to set the value "Position COLD".
The function button [
---
] leaves the position unchanged; function button
[
Stand.
] sets the factory setting.
7.2.3.8 Slat angle COL
This setting is only useful when you have chosen a slat product (external or
internal venetian blinds). If you have connected a slat product (such as an ex-
ternal venetian blind), you can specify how the slats are to be set after move-
ment to the "COLD" position is completed. This is especially useful if you
prefer a specific setting. In addition, you must no longer tilt the slats manually
after automatic movement. The temperature control tilts the slats automati-
cally if programmed accordingly.
Turn the touch wheel to set the value "Slat angle COLD".
The function button [
---
] leaves the slat angle unchanged; function button
[
Stand.
] sets the factory setting.
7.2.3.9 Operating mode, selecting
Five operating modes are available for the temperature control:
Direct control
Enable/disable sun
Enable/disable difference temperature
Direct control with steps
Difference temperature with steps
irect control
This operating mode simply triggers move commands only, when the limit
value is exceeded of fallen below.
Gnable/disable sun
This operating mode is called "Temperature-controlled sun control" and can
be used to enable/disable the sun control.
(It must first have been activated by setting the checkmark in the
[
Sun control
] menu).
Example
For example, on a cold clear winter day the sun should first heat up your
conservatory before the sun shading product becomes active, after all, the
sun is the most economic source of heating. You can therefore program the
Wisotronic so that the automatic sun control is only released at a specific
inside or outside temperature. Here you will use the “Enable/disable sun” op-
erating mode (=temperature-controlled sun control).
Uemperature control