![WAREMA Wisotronic Operating Instructions Manual Download Page 52](http://html2.mh-extra.com/html/warema/wisotronic/wisotronic_operating-instructions-manual_3377277052.webp)
890557_d•en•01.07.2014
We reserve the right to carry out improvements
52
Wisotronic 1-channel
Operating instructions
7.2.3.3 Limit value WDEM
The "WARM" limit value specifies the temperature at which a sun shading
product is to be lowered.
Example
For example, you may want the inside temperature of your conservatory to
kept at a bearable level on hot summer days. Therefore, you can tell the
Wisotronic at which temperature value the sun shading product is to be low-
ered to give shade to the conservatory.
Turn the touch wheel to set the limit value "WARM".
The function button [
---
] deactivates the assessment; the function button
[
Stand.
] sets the factory setting.
7.2.3.4 Position WDEM
The "Position WARM" value specifies the position to which a sun shading
product is to be moved. The setting range is 0-100%; a value of 0% cor-
responds to the upper limit position and a value of 100% to the lower limit
position.
Turn the touch wheel to set the value "Position WARM".
The function button [
---
] leaves the position unchanged; function button
[
Stand.
] sets the factory setting.
7.2.3.5 Slat angle WDEM
This setting is only useful when you have chosen a slat product (external or
internal venetian blinds). If you have connected a slat product (such as an
external venetian blind), you can specify how the slats are to be set after
lowering to the "WARM" position is completed. This is especially useful if you
prefer a specific setting. In addition, you do not have to tilt the slats up after
automatic movement. The temperature control tilts up the slats automatically
if programmed accordingly.
Turn the touch wheel to set the value "Slat angle WARM".
The function button [
---
] leaves the slat angle unchanged; function button
[
Stand.
] sets the factory setting.
7.2.3.6 Limit value COL
The value “COLD” specifies at which temperature a sun shading product
shall be raised.
Example
For example, you may want the sun to help heat your conservatory on cold
clear winter days. Therefore, you can tell the control at which temperature the
sun shading product is to be raised to allow sunlight into the conservatory.
The setting range is -10...+50 °C.
Turn the touch wheel to set the limit value “COLD”.
The function button [
---
] deactivates the assessment; the function button
[
Stand.
] sets the factory setting.
Uemperature control