WAREMA MSE Compact 1 UP Operating And Installation Instructions Download Page 1

warema_890022_alhb_en_v3•2020-10-01

We reserve the right to carry out improvements

1

Operating and Installation Instructions 

MSE Compact 1 UP

Keep for future use!

Valid from October 1st, 2020

General

Fig. 1 

MSE Compact 1 UP

The motor control unit MSE Compact 1 UP is an electronic 

control unit for the direct control of 230 V AC sun protec-

tion drives. The drives and the MSE Compact 1 UP are 

supplied via the 230 VAC main line. In spite of its compact 

design, the device is equipped with a built-in power supply 

which provides the internal supply voltage. Furthermore, 

the MSE Compact 1 UP comes with a switch to select 

time logic (factory-set) or permanent logic to permit type-

specific operation of various sun protection systems. It is 

intended for installation in a deep flush-mounted switch 

box.

The sun protection system can be operated through local 

pushbuttons as well as through a central sun protection 

control unit (e.g. Wisotronic). Several MSE Compact 1 

UP can be combined in a group and operated jointly by 

means of a single pushbutton.

Intended use

The device was developed to control sun shading systems. 

The approval of the manufacturer must be obtained for 

uses outside of the purposes listed in these instructions.

Safety instructions

ARNING

W

 

Electrical installation must be performed 

by a certified electrician in accordance 

with VDE 0100 or the legal requirements 

and standards of the country in which the 

device is being installed. The electrician 

must observe the installation instruc-

tions included with the supplied electrical 

devices.

WARNING

If hazard-free operation cannot be as-

sumed, the device may not be started or 

must be deactivated. This assumption is 

justified

 

     

if the housing or the supply lines show 

signs of damage, 

  

 

the device is no longer working

WARNING

It is important to comply with the follow-

ing points of instruction in the interest of 

personal safety!

  Do not allow children to play with the operating ele-

ments of the control or remote control! Store the re-

mote controls out of range from children!

  Make sure that no persons or objects are in the range 

of movement of the driven parts (blinds, window, etc.!

  Disconnect the device from the supply voltage if clean-

ing or other maintenance work must be performed!

Information on the electrical installation

An on-site overload current disconnecting and isolating 

switch to switch off the entire system must be provided.

When using control lines according to VDE 0815 or not 

approved for 230 V AC, e.g. JY(St)Y leads, the enclosed 

silicon tubes must be pulled over the wires of of the 24 V-

control line and the pushbutton line.

The device meets the EMC guidelines for use in residential 

and commercial areas.

Mounting

The MSE Compact 1 UP is intended for flush-mounted 

installation in a commercially available deep flush-mounted 

switch box ∅ 60 mm; the installation in a deep flush-

mounted splitting box ∅ 70 mm is recommended. Only 

lines for the wiring of the MSE Compact 1 UP should be 

routed through this box. 

OTICE 

N

Only one MSE Compact 1 UP may be installed 

per flush-mounted box.

OTICE 

N

Set the encoding switch S1 according to the 

desired function (Fig. 4)

The installation must be done indoors! The device is not 

suitable for use in rooms requiring moisture-proof installa-

tions! The electrical connection of the MSE Compact 1 UP 

is made with spring-loaded terminals (Fig. 3) according to 

the following wiring diagram (Fig. 4).

Commissioning

The device is ready for operation after the installation has 

been completed and the supply voltage applied.

Summary of Contents for MSE Compact 1 UP

Page 1: ... This assumption is justified if the housing or the supply lines show signs of damage the device is no longer working WARNING It is important to comply with the follow ing points of instruction in the interest of personal safety Do not allow children to play with the operating ele ments of the control or remote control Store the re mote controls out of range from children Make sure that no persons...

Page 2: ... the device that require mainte nance Cleaning Clean the enclosure with a soft damp cloth Do not use any scouring agents solvents or steam cleaners Liability Failure to comply with the product information in these instructions and use of the device in a manner that con travenes its intended use and purpose may result in the manufacture refusing to honour warranty claims for prod uct damage In this...

Page 3: ...ation of the wire enters the terminal and the lead is held securely in the terminal 2 To detach the connection the corresponding unlocking button must be pushed all the way in with a screwdriver the lead can then be pulled out of the terminal 3 Fig 4 Wiring diagram 24 0 mm 48 5 mm 48 5 mm Fig 2 Housing dimensions 2 3 Fig 3 Connecting and detaching the line connections ...

Page 4: ...bn bk bl gnyl bn bk 0 V Central down Central up Group down Group up to next MSE F P Connection Floating contacts of the sun shading control system GA Compact DOWN UP E P C For further information see documentation to wiring diagrams Anschlusspläne Art No 816 345 Max group size of 200 motor control units see voltage drop diagram Central control line length see voltage drop diagram The power line le...

Reviews: