Technical data
KNX SA 4MDC.8 AP
min.
typ.
max.
Unit
Operating voltage (SELV)
21.6
24
26.4
V DC
Current consumption in
standby mode
6.1
mA
Current consumption with
four
activated relays
45.9
mA
Nutput per drive
Switching capacity per
output at 24 V DC
20
72
W
Interface KNX
TP 1
Current consumption KNX
3.5
13
mA
Voltage
29
V DC
Conformity
can be viewed at www.warema.com
This device complies with the EMC directives for use in
residential and commercial areas.
Inputs on local operating elements (sunblind push buttons,
1-pin) and signal inputs
Voltage, active
8
24
36
V DC
Current, active
0.5
1
1.5
mA
Voltage, inactive
-0.5
0
1
V DC
Bluetooth transceiver
Transmission frequency
2.402
2.408
GHz
Transmission power
0
dBm
Reception sensitivity
-90
dBm
Operating range (environ-
ment without interference)
5
m
Ambient conditions
Operating temperature
0
50
°C
Storage temperature
0
70
°C
Humidity
(not condensing)
10
40
85
%F
rel
Connection
Connecting line
Screw terminals
KNX bus system, drives,
push button inputs
Spring terminals
Wire cross sections
Connecting line
max. 2.5 mm²
KNX bus system
0.6 - 0.8 mm
∅
Motor outputs,
push button inputs
max. 1.5 mm²
Housing
Degree of protection
Surface-mounted housing
IP30
Safety class
(PE is looped through)
III
Miscellaneous
Automatic operation
Type 1
Software class
A
Location of use
clean ambient conditions
Article numbers
KNX SA 4MDC.8 AP
2014 573
WAREMA Renkhoff SE
Hans-Wilhelm-Renkhoff Strasse 2
97828 Marktheidenfeld
Germany
119 mm
180 mm
60 mm
3 ‒ 4 mm
106 mm
80 mm
Fig. 3
Dimensions of surface-mounted housing 6 MW