07610-004-37-37-P
3
Operating Capacity: UH30-FND UL30
Racks per Hour
24
24
Dishes per Hour
600
600
Glasses per Hour
864
864
Gallons per Rack
1.1
1.2
Gallons per Hour
26.4
28.8
Tank Capacity (Gallons):
Wash Tank
1.1
1.2
Rinse Tank
3.0
N/A
Electrical Loads (as applicable):
Wash Motor HP
1.0
1.0
Rinse Heater kW 6.7 (208 V)/8.2 (230 V)
N/A
Wash Heater kW
N/A
1.5
Always refer to the machine data plate for specific electrical and water
requirements. The material provided on this page is for reference only and is
subject to change without notice.
HOT WATER SANITIZING
Water Temperatures (°F):
Minimum Wash Temperature
150
N/A
Minimum Rinse Temperature
180
N/A
Minimum Incoming Water Temperature
110
N/A
CHEMICAL SANITIZING
Water Temperatures (°F):
Minimum Wash Temperature
N/A
120
Minimum Rinse Temperature
N/A
120
Minimum Incoming Water Temperature
N/A
120
Other Water Requirements:
Water Flow Pressure (PSI)
20 ± 5
20 ± 5
Flow Rate Minimum (GPM)
6.6
6.6
Water Line Connection Size (NPT) 3/4" GHT
3/4" GHT
Water Line Size (NPT)
1/2"
1/2"
Drain Line Size (NPT)
1" ID
1" ID
Install drain line into MIN 1 1/2" Drain with Air-gap.
Minimum Chlorine Required (PPM)
N/A
50
OPERATING PARAMETERS
SPECIFICATIONS
NOTICE
i
NOTICE