07610-004-37-37-P
7
Electrical and grounding conductors must comply with the applicable portions of the
National Electric Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.
The data plate is located at the left-front side of the dishmachine. Refer to the data
plate for machine operating requirements, machine voltage, total amperage, and serial
number.
Remove the back panel and set aside. This will require removing the screw at the
bottom of the back panel with a phillips screwdriver. Install 3/4” conduit into the pre-
punched holes in the back of the control box. Route power wires and connect to power
block and grounding lug. Install the service wires (L1 and L2 for UH30-FND, L1 and
N for UL30) to the appropriate terminals as they are marked on the terminal block.
Install the grounding wire into the lug provided. It is recommended that “DE-OX” or
another similar anti-oxidation agent be used on all power connections.
UH30-FND
UL30
Ensure the ON/OFF switch is in the OFF position and apply power to dishmachine.
Check the incoming power at the terminal block and ensure it corresponds with the
voltage listed on the data plate. If not, contact a qualified service agency to examine
the problem. Do not run dishmachine if voltage is too high or too low. Shut-off the
service breaker and advise all proper personnel of the location of the breaker and
any problems. Replace the control box cover and tighten-down the screws.
This is a commercial dishmachine and reaches temperatures that can exceed
those generated by a residential machine. Surrounding countertops, cabinets, flooring
material, and subfloor material must be designed and/or selected with these higher
temperatures in mind.
Any damage to surrounding area that is caused by heat and/or moisture to materials
that are not recommended for higher temperatures will not be covered under warranty
or by the manufacturer.
The thermostats on this dishmachine have been set at the factory. They should only
be adjusted by an authorized service agent.
INSTRUCTIONS
INSTALLATION
ELECTRICAL POWER
CONNECTIONS
Disconnect electrical
power at the breaker or
disconnect switch and
tag-out in accordance with
procedures and codes.
THERMOSTATS
SURROUNDING
AREA
VOLTAGE CHECK
NOTICE
i
L1 L2
GRND
L1 N
GRND