Wantec 5714 Quick Installation Manual Download Page 1

1. Use CAT5e or CAT6 UTP/STP cables and RG6 coaxial cables. 

2. Please avoid using low quality cables, which will seriously limit the cabling distance and power delivery. 

3. Make sure the ventilation openings on the EPoC Adapter are not blocked. 

5714/5715 Outdoor EPoC Adapter

 

 

Model

Description

5714

Outdoor 1 port EPoC Tx Adapter, 1x BNC, 1x FE RJ45, -30ºC~60ºC

5715

Outdoor 2 port EPoC Tx Adapter, 1x BNC, 2x FE RJ45, -30ºC~60ºC

IMPORTANT

INTRODUCTION

CONNECTION

PACKAGE CONTENTS

Quick Installation Guide

* 1x Outdoor EPoC Adapter

* 1x Quick Installation Guide

* 1x Gray Rubber for 6~8mm coaxial cable

* 1x Black Rubber for 4.5~6.5mm coaxial cable

Ethernet w/PoE

Ethernet

Coax w/Power

1200m(3937ft)

5710

Network Switch

5714

5711

UPoE Switch

1200m(3937ft)

Surge Protector

Surge Protector

5715

NOTE: 

The Outdoor EPoC Adapter & Surge Protector must be 

grounded using a ground wire between the

 

ground screw and 

earth ground.   

     IMPORTANT:

Ground screw

* Make sure the grouning

resistance is lower than 

0.5

Ω.

5714:

5715:

To disconnect a LAN cable, loosen the cable

gland and pull the cable against the socket

wall towards the side of the locking tab.   

 NOTE:

For further protection against water ingress and high temperature , it is recommended to locate the unit where possible:

• Horizontal installation

• Shaded from sunlight & rainfall

INSTALLED

 

LOCATION