1. Use CAT5e or CAT6 UTP/STP cables and RG6 coaxial cables.
2. Please avoid using low quality cables, which will seriously limit the cabling distance and power delivery.
3. Make sure the ventilation openings on the EPoC Adapter are not blocked.
5714/5715 Outdoor EPoC Adapter
Model
Description
5714
Outdoor 1 port EPoC Tx Adapter, 1x BNC, 1x FE RJ45, -30ºC~60ºC
5715
Outdoor 2 port EPoC Tx Adapter, 1x BNC, 2x FE RJ45, -30ºC~60ºC
IMPORTANT
:
INTRODUCTION
CONNECTION
PACKAGE CONTENTS
Quick Installation Guide
* 1x Outdoor EPoC Adapter
* 1x Quick Installation Guide
* 1x Gray Rubber for 6~8mm coaxial cable
* 1x Black Rubber for 4.5~6.5mm coaxial cable
Ethernet w/PoE
Ethernet
Coax w/Power
1200m(3937ft)
5710
Network Switch
5714
5711
UPoE Switch
1200m(3937ft)
Surge Protector
Surge Protector
5715
NOTE:
The Outdoor EPoC Adapter & Surge Protector must be
grounded using a ground wire between the
ground screw and
earth ground.
IMPORTANT:
Ground screw
* Make sure the grouning
resistance is lower than
0.5
Ω.
5714:
5715:
To disconnect a LAN cable, loosen the cable
gland and pull the cable against the socket
wall towards the side of the locking tab.
NOTE:
For further protection against water ingress and high temperature , it is recommended to locate the unit where possible:
• Horizontal installation
• Shaded from sunlight & rainfall
INSTALLED
LOCATION
: