91
W&T
Mode TCP server
Subject to error and alteration
11�1�1 Configuration of the local port number
SETUP Port x
TCP/IP Mode
...
Port List
...
Local Port TCP/UDP
To open a connection to the Com-Server, a client needs an
IP address and the TCP port number. Direct access via TCP
to the serial port of the Com-Server is done using the port
number stored in the menu branch
Setup Port x
r
TCP/IP
Mode
r
Port List
r
Local port (TCP)
. Port number 8000 is pre-
configured at the factory
11�1�2 Optional settings
Serial transmission parameters
SETUP Port x
UART Setup
...
Baud, Parity, Data Bits,
Stopbits, Handshake
Baud rate, data bits, parity and handshake procedure must
conform to the connected serial device. For details see section
Configuration of the Serial Port
.
Serial receive buffer
SETUP Port x
UART Setup
...
Receive Buffer
...
The Com-Server has a variable serial receive buffer of approx.
4kB. The menu item allows this value to be reduced. Whether
the serial receive buffer is automatically cleared when a con-
nection is opened or any existing older data are sent to the
Summary of Contents for Com-Server++
Page 8: ...W T...
Page 26: ...26 W T Assigning the IP address...
Page 27: ...27 W T Subject to error and alteration 3 Supply voltage Com Server Com Server3x Isolated...
Page 30: ...30 W T Supply voltage...
Page 34: ...34 W T Network interface...
Page 41: ...41 W T Subject to error and alteration 6 LED displays Power Status Error LED Network LEDs...
Page 88: ...88 W T Packetizing serial datagrams...
Page 94: ...94 W T Mode TCP server...
Page 108: ...108 W T Mode TCP client...
Page 122: ...122 W T UDP bus mode...
Page 130: ...130 W T The Windows COM port redirector...
Page 138: ...138 W T Box to Box mode...
Page 154: ...154 W T Mode FTP client...
Page 164: ...164 W T Mode Telnet Client...
Page 182: ...182 W T OPC data transfer...
Page 186: ...186 W T Mode InQueueCopy...