38
W&T
The serial combi-port
5�3
RS422/485 mode
As opposed to RS232, an RS422 interface allows transmission
distances of up to 1000 meters. The RS485 mode allows you
to integrate corresponding 2- or 4-wire bus sytems into a
TCP/IP network with the help of the Com-Server.
1
Especially when using longer cable lengths in
industrial environments, potential differences need to be
taken into consideration. To prevent transmission problems
and hardware damage caused by this, we recommend galva-
nic isolation using an external isolator
(e.g. W&T RS422/485-
Isolator Type 66201)
.
DIP switch settings
Mode
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
RS422, RS485
4-wire bus master
OFF
OFF
OFF
OFF
ON
Term.
OFF
RS485 4-wire
automatic control
OFF
ON
OFF
OFF
ON
Term.
OFF
RS485 2-wire
automatic control
ON
ON
OFF
OFF
OFF
Term.
OFF
Pin assignment and function RS422/485, DB9 male
Pin
Direction
Signal
Description
Default function (*)
1
OUT
TxD A/-
Transmit Data A
Data out
2
IN
RxD A/-
Receive Data A
Data in
3
OUT
RTS A/-
Ready To Send A
Handshake out
4
IN
CTS A/-
Clear To Send A
Handshake in
5
---
GND
Signal Ground
---
6
OUT
TxD B/+
Transmit Data B
Data out
7
IN
RxD B/+
Receive Data B
Data in
8
OUT
RTS B/+
Ready To Send B
Handshake out
9
IN
CTS B/+
Clear To Send B
Handshake in
(*)
Applies only to the hardware handshake setting
Summary of Contents for Com-Server++
Page 8: ...W T...
Page 26: ...26 W T Assigning the IP address...
Page 27: ...27 W T Subject to error and alteration 3 Supply voltage Com Server Com Server3x Isolated...
Page 30: ...30 W T Supply voltage...
Page 34: ...34 W T Network interface...
Page 41: ...41 W T Subject to error and alteration 6 LED displays Power Status Error LED Network LEDs...
Page 88: ...88 W T Packetizing serial datagrams...
Page 94: ...94 W T Mode TCP server...
Page 108: ...108 W T Mode TCP client...
Page 122: ...122 W T UDP bus mode...
Page 130: ...130 W T The Windows COM port redirector...
Page 138: ...138 W T Box to Box mode...
Page 154: ...154 W T Mode FTP client...
Page 164: ...164 W T Mode Telnet Client...
Page 182: ...182 W T OPC data transfer...
Page 186: ...186 W T Mode InQueueCopy...