25
Section 5:
Electrical Installation
How to wire a DIN connector
Models PD0046 - PD0360
•
Locate the DIN connector on the back of the controller.
•
Remove the screw completely from the centre of the
connector.
•
Remove the blanking plug, if present, from the
connector and discard.
•
Insert a small flat screwdriver into the small recess at
the edge of the insert, pry the insert out of the DIN
connector’s outer shell per figure 5.3.
•
Per figure 5.4, slip cable end through DIN connector’s
cable gland, washer, grommet and out through the
front of the DIN connector case.
•
Strip the outer insulation of the cable back approx
20mm (3/4”).
•
Strip the conductor insulation back approx 3mm (1/8”).
•
Insert conductors into appropriate pins of insert.
Tighten retaining screws securely.
•
Determine which direction the cable gland should
point.
•
Carefully pull the cable back through the case until the
insert snaps back into place. Take care to work the wires
around the retaining screw hole as they can become
fairly easily pinched.
•
Plug the DIN connector back onto the appropriate
electrical connection on the back of the dryer’s
controller per figure(s) 5.1 and 5.2. Take care to make
sure that sealing gasket is in place.
Cable diameter should be no greater than 6mm
(1/4”). Larger diameters do not fit well into the
cable gland of the DIN connectors.
Cable should be round as rectangular cable
or ribbon cable will not seal properly in DIN
connectors grommet.
The male ground pin is slightly wider than
pins 1 & 2. Take care to ensure that the female
connector is oriented correctly.
25
PRODRY PD0046 - PD0360 Instruction Manual
|
Walker Filtration
|
Section 5: Electrical Installation
How to wire a DIN connector
Fig ure 5.3 : DIN conn ecto r
Fig ure 5.4 : DIN co nnect or for LED and DMC C ontrolle r
•
Locate the DIN connector on the back of the controller.
•
Remove the screw completely from the centre of the
connector.
•
Remove the blanking plug, if present, from the connector
and discard.
•
of the insert, pry the insert out of the DIN connector’s outer
shell per ure 5.3.
•
p cable end through DIN connector’s cable
gland, washer, grommet and out through the front of the
DIN connector case.
• Strip the outer insulation of the cable back approx 20mm
(3/4”).
• Strip the conductor insulation back approx 3mm (1/8”).
• Insert conductors into appropriate pins of insert. Tighten
retaining screws securely.
• Determine which direction the cable gland should point.
•
Carefully pull the cable back through the case until the insert
snaps back into place. Take care to work the wires around the
retaining screw hole as they can become fairly easily pinched.
•
Plug the DIN connector back onto the appropriate electrical
5.1 and 5.2.
Take care to make sure that sealing gasket is in
place.
The male ground pin is slightly wider than pins 1 & 2.
Take care to ensure that the female connector is
oriented corectly.
Cable diameter should be no grea ter than 6mm (1/4”).
La
rg
er diameters do not fit well into the cable gland of
the DIN connectors.
Cable should be round as rectangular cable or ribbon
cable will not seal properly in DIN connectors
grommet.
20 mm
3 mm
Outer insulation
must extend
through grommet
to ensure that
IP65 specification
is met
Gasket
Insert
Case
Grommet
Washer
Cable
Cable Gland
Figure 5.3: DIN connector
25
PRODRY PD0046 - PD0360 Instruction Manual
|
Walker Filtration
|
Section 5: Electrical Installation
How to wire a DIN connector
Fig ure 5.3 : DIN conn ecto r
Fig ure 5.4 : DIN co nnect or for LED and DMC C ontrolle r
•
Locate the DIN connector on the back of the controller.
•
Remove the screw completely from the centre of the
connector.
•
Remove the blanking plug, if present, from the connector
and discard.
•
of the insert, pry the insert out of the DIN connector’s outer
shell per ure 5.3.
•
p cable end through DIN connector’s cable
gland, washer, grommet and out through the front of the
DIN connector case.
• Strip the outer insulation of the cable back approx 20mm
(3/4”).
• Strip the conductor insulation back approx 3mm (1/8”).
• Insert conductors into appropriate pins of insert. Tighten
retaining screws securely.
• Determine which direction the cable gland should point.
•
Carefully pull the cable back through the case until the insert
snaps back into place. Take care to work the wires around the
retaining screw hole as they can become fairly easily pinched.
•
Plug the DIN connector back onto the appropriate electrical
5.1 and 5.2.
Take care to make sure that sealing gasket is in
place.
The male ground pin is slightly wider than pins 1 & 2.
Take care to ensure that the female connector is
oriented corectly.
Cable diameter should be no grea ter than 6mm (1/4”).
La
rg
er diameters do not fit well into the cable gland of
the DIN connectors.
Cable should be round as rectangular cable or ribbon
cable will not seal properly in DIN connectors
grommet.
20 mm
3 mm
Outer insulation
must extend
through grommet
to ensure that
IP65 specification
is met
Gasket
Insert
Case
Grommet
Washer
Cable
Cable Gland
Figure 5.4: DIN connector for LED and DMC Controller