Page 1: ...I In ns st tr ru uc ct ti io on n M Ma an nu ua al l Automatic Wrist Blood Pressure Monitor M Mo od de el l N No o H HL L1 15 58 8H HD D 1 ...

Page 2: ...07 Device Overview 09 Symbol Definitions 11 Features 12 Installing Batteries 16 Applying the Cuff 17 Positioning Guide 18 Measurement Procedure 19 Bluetooth Transmission 21 Memory Function 22 Storage and Maintenance 23 Troubleshooting 24 Warranty Recalibration 25 Specifications 26 Note 28 Appendix 29 Blood Pressure Diary 31 2 ...

Page 3: ...ct that you have a medical problem promptly consult your healthcare provider Intended Use This device uses the oscillometric method to automatically measure systolic and diastolic blood pressure as well as heart rate The measurement position is at human being s wrist All values can be read out in one LCD panel The device is designed for home use and recommended for use by adults aged 18 years and ...

Page 4: ...the afternoon to the evening It is on average lower in the summer and higher in the winter 2 Why is it useful to measure blood pressure at home Having one s blood pressure measured by a doctor in a hospital or a clinic is often associated with a phenomenon called White Coat Hypertension where the patient becomes nervous or anxious thus raising his blood pressure There are also numerous other facto...

Page 5: ...cian for proper diagnosis B Variations in blood pressure Individual blood pressures vary greatly both on a daily and a seasonal basis These variations are even more pronounced in hyper tense patients Normally the blood pressure rises while at work and is at its lowest during sleeping period hyper tense means a person who has high blood pressure symptom The graph below illustrated the variations in...

Page 6: ...e monitor measures these contractions and converts the information to a digital value This is the result displayed on the monitor screen Once the measurement is complete the cuff will automatically deflate Accuracy HL158HD Automatic Wrist Blood Pressure Monitor has been clinically tested against a scientific device called a mercury sphygmomanometer considered the gold standard in blood pressure me...

Page 7: ...nt if you ve just consumed caffeinated beverages or smoked cigarettes Rest at least 5 10 minutes before taking a measurement To allow your blood vessels to return to the condition prior to taking the measurement please wait at least 3 5 minutes in between measurements You may need to adjust the wait time according to your personal physiological situation We recommend you using the same wrist prefe...

Page 8: ...s and pregnant women Blood pressure measurements taken with this device are equivalent to those obtained by a trained observer using the cuff stethoscope auscultation method and are within the accuracy limits prescribed by the American National Standard for Manual electronic or Automated Sphygmomanometers Attention 1 Do not use the device on infants children or those who cannot express their own i...

Page 9: ...TOP BUTTON AAA LR03 1 5V ALKALINE BATTERY X 2 STORAGE CASE Caution Substitution of a component different from that supplied might result in measurement error MODE BUTTON MEMORY BUTTON RISK CATEGORY INDICATOR User Select BUTTON BLUETOOTH Indicator BUTTON 9 ...

Page 10: ...it display Heart Rate Low Battery Symbol User 1 User 2 Hour Minute Month Date Year Pulse Symbol Diastolic Rate Systolic Rate Risk Category Indicator Irregular Heartbeat Detector Error Symbol The last 3 Average Symbol 10 ...

Page 11: ...ector This symbol appears for 1 minute when the user was talking moving shaking or an irregular heart beat was detected during measurements Our suggestion Please do not talk or move during measurements Repeat the measurement after resting for at least 5 minutes and restart your measurement while sitting down comfortably and quietly User 1 User 1 Appears when the monitor is operated by User 1 User ...

Page 12: ...esent your measuring result Refer to below comparison chart for details After each measurement is completed LCD displays the stages of blood pressure symbols will depend on your readings and corresponds to Risk Category Indicator Stages of Blood Pressure Levels Systolic mmHg Diastolic mmHg Important Notice Stage 2 Hypertension 160 100 You may use the function to effectively track your blood pressu...

Page 13: ...sure for people with diabetes and chronic kidney disease A blood pressure of 130 80 mmHg or higher is considered high blood pressure for those individuals Note The above table is not exact for classification of blood pressure and it s intended to be used as a guide in understanding non invasive blood pressure measurements Usually this is not a cause for concern however we recommend you consult wit...

Page 14: ...ty is detected during measurement often we recommend you seek medical advice As a safeguard we recommend that if you have arrhythmias such as atrial or ventricular premature beats and atrial fibrillation or any other special conditions you should check with your physician before using your device The IHB function is not designed for use by people with arrhythmias nor for diagnosing or treating an ...

Page 15: ...ss devices that are in use nearby such as a cell or mobile phone or a wireless network may prevent or delay the transmission of data from your device to paired Bluetooth device Moving away from the source of the interference or turning off these devices to resolve the problem Make sure HL158HD and paired Bluetooth device are within acceptable distance no more than 10 meters with each other If not ...

Page 16: ...the battery compartment as shown on the figure below Make sure the polarities and ends are properly positioned Attention Batteries are hazardous waste Do not dispose of them together with the household garbage Please discard worn out batteries to the recycling site according to local regulations Keep the battery away from children in case they choke on it If the device is not to be used for over 2...

Page 17: ...rap the cuff snugly Do not make it too tight Fold the remaining part of the cuff back out of the way Leave approximately 0 4 inch 10 mm between the cuff and the bottom of your hand palm Note Do not use this device if your wrist has any wound or injury Do not wrap the cuff around any body part other than your wrist 0 4 inch 10 mm 5 3 7 7 inch 135 195 mm 17 ...

Page 18: ... results 1 Sit down comfortably with your feet flat on the floor 2 Position the blood pressure monitor on your wrist 3 Place your elbow on the table and rest the back of your hand on the device storage case or other object 4 Rest your wrist on the armrest until it s at the same height as your heart 5 Relax your hand and turn your palm upwards 18 ...

Page 19: ... 3 31 HOUR 1 2 3 12PM 1 PM 12 and MINUTE 00 01 02 03 59 as described in Step A above When settings are done press button to confirm the entries The device is ready to measure Turning Bluetooth Feature ON OFF User can press and hold START STOP button 3 seconds to turn the Bluetooth feature ON OFF in Sleeping Mode Note The Bluetooth Feature Switch default setting is ON Taking a Measurement A Before ...

Page 20: ...matically inflate to the level that is right for you C After inflation of the cuff the pressure will slowly decrease When pulse is detected PULSE SYMBOL flashes Note If the cuff does not stop inflating remove the cuff at once To stop measurement press button D LCD screen displays your systolic rate diastolic rate pulse Risk Category Indicator icon and Irregular Heartbeat Detector symbol if any wit...

Page 21: ...ease redo Steps1 2 Press and hold button for 3 seconds Under Sleeping Mode and Standby Mode 1 Press and hold button for 3 seconds to wake up the device and starting Bluetooth function Bluetooth Indicator flashing 2 While transmitting the reading to your Bluetooth Device HL158HD Bluetooth Indicator will remain steady on the screen 3 HL158HD can only pair up with one Bluetooth device at a time To tr...

Page 22: ...M button to enter Memory Mode LCD displays average of last 3 measuring results first C Press M button again LCD displays the latest measuring result Use button to scroll through all stored measuring results D To stop reading memories press button and switch to Standby Mode Erasing data A Press button to select User 1 or 2 B Press M button to enter Memory Mode C Press and hold and buttons at the sa...

Page 23: ...of the monitor including wrist cuff due to substitution of a component different from that supplied might result in measurement error If any suggestion or service is requested please consult your service station Storage If the device is not to be used for a long time please remove the batteries from the device leaking of battery acid can cause the device to malfunction Always store the unit in the...

Page 24: ...Symbol Error determining measurement data Measure again Fail Connection Error Symbol HL158HD cannot connect to Bluetooth enabled device over 45 seconds Please refer to Page 21 Bluetooth Transmission to retry again BPM cannot communicate with Bluetooth enabled device Bluetooth enabled device does not pair with BPM or pair with a wrong device Please re pairing the BPM and Bluetooth enabled device wi...

Page 25: ...mmended maintenance transportation damage theft neglect vandalism or environmental conditions loss of use during the period the product is at a repair facility or otherwise awaiting parts or repair or any other conditions whatsoever that are beyond the control of importers or distributors Recalibration Notice To ensure continued measurement precision all digital blood pressure monitors require rec...

Page 26: ... 1 29 inch L X W X H Unit Weight Cuff Batteries Excluded 142 5 g 5 g 5 03 oz 0 18 oz Cuff Size 135 195 mm 5 3 7 7 inch Storage Transportation Environment Temperature 25 C 70 C 13 F 158 F Humidity 93 R H Operation Environment Temperature 5 C 40 C 41 F 104 F Humidity 15 93 R H Power Supply DC 3 V AAA LR03 1 5V Alkaline Battery x 2 Battery Life Approx 200 Measurements Sleeping Mode Without any operat...

Page 27: ...onments Security AES 128 and application layer user defined Wireless Operation Distance Class 2 Maximum 10 meter RF Frequency Need for Spectrum Management 2402 2480 MHz allowing for guard bands Maximum Limitation Unlimited Maximum Permitted Power 2 5 mW Proximity of Other In band Transmitters Used in Vicinity up to 40 bands 2 MHz spacing centered from 2402 to 2480 MHz Wireless Communication Profil...

Page 28: ...ticular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures The user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving ant...

Page 29: ...idity should be at least 30 Power frequency 50 60 Hz magnetic field IEC 61000 4 8 3 A m 3 A m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment Recommended separation distances between portable and mobile RF communication equipment and the device The device is intended for use in an electromagnetic environment w...

Page 30: ... by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures object...

Page 31: ...fore After Meal Systolic Diastolic Pulse Date Time Before After Meal Systolic Diastolic Pulse Date Time Before After Meal Systolic Diastolic Pulse Date Time Before After Meal Systolic Diastolic Pulse Date Time Before After Meal Systolic Diastolic Pulse Date Time Before After Meal Systolic Diastolic Pulse Date Time Before After Meal Systolic Diastolic Pulse P N XXXXXXXXX VER A001 YYYYMMDD 31 ...