background image

 

 

WALDIS Tresore AG 

Riedmattstrasse 12     

¦

     CH-8153 Rümlang     

¦

      Tel. +41 (0)43 211 12 00     

¦

    Fax +41 (0)43 211 12 12     

¦

     www.tresore.ch     

¦

    [email protected] 

 

H:\13 - Freigegebene Dokumente\Anleitungen\CAWI Schloss\CAWI 7215_E.doc 

Oeffnungsdrehgriff

WA-60 - WA-150

Oeffnungsdrehgriff

WA-40/50

MA-41 - MA-84

Using instructions digital code lock "CAWI 7215" 

 

1. 

TO OPEN THE LOCK

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.1.

 

At  the  beginning  turn  the  handle  into  closing  position  (level)  by  turning  it  counterclockwise.  
The lock is in the „sleep mode“ and has to be activated by pressing the button “C and 0” 

1.2.

 

Enter  the  correct  code  (factory  code  “1  2  3  4  5  6”),  the  green  light  flashes  on  once  and  a  high-low 
acoustical signal will be heard. 

1.3.

 

If  the  handle  is  not  turned  clockwise  into  the  opening  position  (at  the  right  angle)  within  
10 seconds the lock will be closed again. 

1.4.

 

Turn the handle into opening position (at the right angle) and wind the door up 

1.5.

 

Every key press will be affirmed by a „peep“. Intermissions longer than 5 seconds will cancel the previous 
entry. An incorrect entry can be cancelled by pressing the button C. 

1.6.

 

If an incorrect entry was made, the red light flashes on and there will be a high acoustical signal for 12 
times. After 3 incorrect entries the lock will be blocked for 12 minutes. Every further incorrect entry will 
extend the blocking time for 12 further minutes. During the blocking time the red light flashes on every 5 
seconds. The ending of the blockage time will be announced by a low acoustical signal and the flashing 
on of the green light.  

1.7.

 

After the blocking time the correct code must be entered and the lock can be opened.  

 

2. 

TO CLOSE THE LOCK 

2.1.

 

Close the door. Turn the handle into closing position (level) by turning it counter clockwise. The electronic 
lock will close automatically.  

 

Handle 

Reviews: