Table 136: Description of the configuration scripts for "HMI Settings"
Parameter
Status Call
Output/Input
Validity
Touchscreen Configuration
Device Name
read
get_touchscreen_
config
device-name
Read device name
Driver Name
read
get_touchscreen_
config
driver-name
Read driver name
immediate
read
get_touchscreen_config
calibrate-touchscreen-flag
Returns text
checked
if
calibration is set.
immediate
Execute
Calibration of
Touchscreen at
Next Start
write
config_touchscreen
calibrate-
touchscreen=<value>
Calibration of the
touchscreen when the I/O-
IPC is started next. Entries
for <value> are:
yes
no
after restart
Keyboard Layout
read
get_coupler_details
keyboard-layout
Keyboard layout:
german
english
Keyboard Layout
write
change_keyboard_layout
keyboard-layout=<value>
Entries for <value> are:
German
English
immediate
Table 137: Description of the configuration scripts for "Administration"
Parameter
Status Call
Output/Input
Validity
Administration
Configuration of Serial Interface
read
get_coupler_details
RS232-owner
User of the serial interface
(RS-232).
Possible values are:
CoDeSys
IO-Check
MODBUS
Linux
None
Configuration of
Serial Interface
write
Config_RS232
owner=<value>
RS-232 user. Entries for
<value> are:
CoDeSys
IO-Check
MODBUS
Linux
None
immediate