Wago - 4PU & 4PS - 38 

 

 

A4.4 Read meter data 

All energy values are located under "Energy", as well as all instantaneous values are located under "Instantaneous". 

Refresh the data using the refresh arrow in the upper right corner. 

 

                    

 

 

Summary of Contents for 4PS

Page 1: ...879 3020 4PS 879 3000 4PU User manual Version 052021V1 1 2021 Wago All rights reserved WAGO Energy Meters MID with Push in CAGE CLAMP and Levers...

Page 2: ...width 17 6 6 6 Modbus ID 17 6 6 7 Modbus Baudrate 18 6 6 8 Modbus parity 18 6 6 9 M Bus ID 18 6 6 10 M Bus baud rate 18 6 6 11 Backlight 19 6 6 12 Powerdown counter 19 6 6 13 Trip counter 19 6 6 14 O...

Page 3: ...cordance with local safety regulations are considered qualified personnel in this manual Use for the intended perpose This device may only be used for the application cases specified in the catalog an...

Page 4: ...high precision components inside that may break and affect the meter measurement negatively All clamps should be properly tightened Make sure the wires fit properly in the connection clamps If the wir...

Page 5: ...ctshould give you years of trouble free operation In case there is a problem with the energy meter you should contact your distributor immediately Most of our energy meters are sealed with a special s...

Page 6: ...6 4PU 4PS Wago 3 Certificates...

Page 7: ...ctive class II Operating temperature range 40 C 70 C Do not exceed the following limits for ambient temperature in combination with conductor cross section and ratedcurrent Artikel Product Leiterquers...

Page 8: ...odulation Uplink signal Slave to master Current modulation Cable JYSTY nx2x0 8 Protocol EN13757 3 Unit loads 1 Max number of meters 64 per bus 4 5 Modbus RS485 communication specification Bus type RS4...

Page 9: ...stranded conductor with insulated ferrule 0 75 16 mm WAGO serie 2604 Solid conductor 0 2 4 mm 24 12 AWG Fine stranded conductor 0 2 4 mm 24 12 AWG Fine stranded conductor with insulated ferrule 0 25 2...

Page 10: ...Klemme Clamp 6 S0 Output 2 Klemme Clamp 7 Modbus A Klemme Clamp 8 Ground for Modbus B MBus Klemme Clamp 9 MBus Klemme Clamp 10 11 Tariff switching 230V AC 4PU 3P3W Delta IN L1 Input Phase L1 OUT L1 O...

Page 11: ...Klemme Clamp 6 S0 Output 2 Klemme Clamp 7 Modbus A Klemme Clamp 8 Ground for Modbus B MBus Klemme Clamp 9 MBus Klemme Clamp 10 11 Tariff switching 230V AC 4PS 3P3W Delta IN L1 Input Phase L1 OUT L1 O...

Page 12: ...d all local regulations Anexternalfuseorthermal cut offused asanovercurrent protectiondeviceforthemetermustbeinstalled onthesupply side wires It s recommended that this protection device is also place...

Page 13: ...1 1 8 2 Positive active energy in tariff 2 1 8 3 Positive active energy in tariff 3 1 8 4 Positive active energy in tariff 4 Reverse 2 8 1 Negative active energy in tariff 1 2 8 2 Negative active ener...

Page 14: ...settings mode press and hold the middle button for 3 seconds The following display will appear 6 5 Bluetooth When the arrows point at the Bluetooth symbol press the middle button to activate Bluetooth...

Page 15: ...also be done using the capacitive touch buttons on the front of the meter Scroll through the options using the left and right button Confirm the setting using the middle button Select the following p...

Page 16: ...S0 Impulsausgang The energy meter is equipped with two pulse outputs forward reverse or active reactive which are optically isolated from the inside circuit It generates pulses in proportion to the me...

Page 17: ...e type setting is active reactive This means that the two pulse outputs pulse based on the active and reactive energy The pulse type can be set to forward reverse which means that the pulse outputs pu...

Page 18: ...4800 2400 1200 600 300 bps 6 6 8 Modbus parity The default Modbus parity setting is even The parity can be modified to none or odd 6 6 9 M Bus ID The M Bus ID can be set from 0 to 250 the default M B...

Page 19: ...on off or button mode 6 6 12 Powerdown counter The powerdown counter registers the number of times that the meter has been turned off 6 6 13 Trip counter The meter is equipped with a trip counter tha...

Page 20: ...41 7 0 forward 42 7 0 reverse L2 Active power 61 7 0 forward 62 7 0 reverse L3 Active power 9 7 0 Total apparent power 29 7 0 L1 Apparent power 49 7 0 L2 Apparent power 69 7 0 L3 Apparent power 3 7 0...

Page 21: ...energy C 01 Nur Bezug Forward only C 02 Nur Liefereung Reverse only C 03 Bezug Lieferung Forward Reverse C 04 Lieferung Bezug Forward Reverse C 05 Bezug Lieferung Forward Reverse saldierende Messung...

Page 22: ...lated tools to maintain or repair the meter Make sure the protection cover is in place after maintenance or repair The case is sealed failure to observe this instruction can result in damage to the me...

Page 23: ...e battery is wrong or cannot be operated bit1 The battery mantissa area cannot be operated bit2 The battery backup area cannot be operated bit3 The main battery storage area cannot be operated bit4 Da...

Page 24: ...230V AC is applied to terminals 10 and 11 the meter switches to tariff 2 and writes the measured values into the the measured values into the registers provided for T2 4PU 4PS A1 2 How to switch betw...

Page 25: ...e default communication address of the meter is 00 The defaults for M bus communication are Baud rate 2400 8 data bits Even parity 1 stop bit 4PU 4PS The secondary addressing 253 FD is preset to the l...

Page 26: ...Wh Reverse active energy T3 84 30 83 3C 15 CD 5B 07 123456789 Wh Reverse active energy T4 84 80 10 83 3C 15 CD 5B 07 123456789 Wh Total kWh resettable 04 83 FC 10 15 CD 5B 07 123456789 Wh Forward rea...

Page 27: ...68 07 07 68 53 01 51 09 FD 3A 05 E5 combined code 05 01 02 03 04 and 05 S0 rate 68 0A 0A 68 53 01 51 0C FD 3A 00 00 01 00 E5 S0 rate 100 10 000 2 000 1 000 100 10 1 0 1 0 01 Resettable kWh 68 09 09 6...

Page 28: ...700 38400 9600 4800 2400 1200 600 and 300 The parity can be set to none or odd Data and stopbit cannot be changed 4PU 4PS When connecting the meter through a serial converter RS485 for testing please...

Page 29: ...ard reverse 4 import export 5 import export 10 4010 LCD cycle time 03 1 sec HEX 4011 Parity setting 03 1 Signed 1 even 2 none 3 odd 4012 Current direction 03 1 ASCII F forward R reverse 4013 L2 Curren...

Page 30: ...at ABCD 5014 L1 Active power 03 2 kW Float ABCD 5016 L2 Active power 03 2 kW Float ABCD 5018 L3 Active power 03 2 kW Float ABCD 501A Total reactive power 03 2 kvar Float ABCD 501C L1 Reactive power 03...

Page 31: ...ive Energy 03 2 kWh Float ABCD 601E L1 Reverse active energy 03 2 kWh Float ABCD 6020 L2 Reverse active energy 03 2 kWh Float ABCD 6022 L3 Reverse active energy 03 2 kWh Float ABCD 6024 Total reactive...

Page 32: ...eactive energy in Q1 total 03 2 kWh Float ABCD 6065 Imp Inductive reactive energy in Q1 T1 03 2 kWh Float ABCD 6067 Imp Inductive reactive energy in Q1 T2 03 2 kWh Float ABCD 6069 Imp Inductive reacti...

Page 33: ...087 Exp capacitive reactive energy in Q4 T3 03 2 kWh Float ABCD 6089 Exp capacitive reactive energy in Q4 T4 03 2 kWh Float ABCD 608B Resettable day counter L1 03 2 kWh Float ABCD 608D Resettable day...

Page 34: ...1 Parity setting 06 1 Signed Command 01 06 4011 0002 new parity none 01 even 02 none 03 odd 4016 Power down counter 06 1 Signed Command 01 06 4016 0000 Reset to 0 6048 Tariff 06 1 Signed Command 01 06...

Page 35: ...d used is standard used is BLE 4 2 You can download the smartphone app for Android and IOS free of charge from the stores You can find the smartphone app under the name WAGO Energy Meter Configurator...

Page 36: ...r Scan QR function 1 Scan Bluetooth The app scans for all Bluetooth measurement devices in the vicinity Select the correct serial number for the connection 2 Scan QR The app opens the camera of the ce...

Page 37: ...37 4PU 4PS Wago A4 3 Device page The energy meter is now connected to the smartphone app The meter type serial number software version and checksums are displayed on the device page...

Page 38: ...U 4PS 38 A4 4 Read meter data All energy values are located under Energy as well as all instantaneous values are located under Instantaneous Refresh the data using the refresh arrow in the upper right...

Page 39: ...ago A4 5 Save meter data Save the data using the memory disk in the upper right corner The data can be stored locally on the smartphone or shared through various channels such as email Bluetooth or ot...

Page 40: ...change The changed settings are highlighted in green Save the values via the memory disk in the upper right corner First a pop up menu for the password appears By default the password is always 0000...

Page 41: ...ontakttechnik GmbH Co KG All rights reserved The content and structure of the WAGO websites catalogs videos and other WAGO media are subject to copyright The distribution or modification of the conten...

Reviews: