82
VERSION 10/2018
ORDER NUMBER DOC 2339321
.
8.3
MALFUNCTION
If a fault occurs, it is indicated by the following:
The system stops and the alarm horn sounds
The alarm display lights up (control unit and remote control).
A fault is indicated on the display.
Acknowledge fault
With the [Stop] button.
Alarm me fault rectification
see Chapter
.
8.4
EMERGENCY DEACTIVATION
In the case of unforeseen occurrences, immediately:
1. Switch off air supply.
2. Vent air motors for all pumps.
3. Provide grounded metal tanks for return product.
Relieve pressure from all the pumps via the return valves.
4. Point the spray gun into the grounded metal tank for return product.
Release and open spray gun to relieve the pressure. Avoid splashback.
5. When no further overpressure is detected, close and secure the spray gun.
B_04457
1.
3.
B_04459
4.
5.
On
Off
Open
Closed
B_04458
2.