6.6
COMMISSIONING
6.6.1 PREPARATION BEFORE COMMISSIONING
Make sure that the device and all other conductive parts within the work area are
grounded.
Connect spray gun without nozzle with high-pressure hose to the mixing unit and
secure with safety clip.
Check hoses for damage.
Check that all product-conveying connections are correctly connected.
Check all connections for leaks.
Check that all connections carrying air are connected correctly according to the
pneumatic diagrams in Chapter
Visually check the permissible pressures for all the system components.
Check level of separating agent in the pumps and top up separating agent if
necessary.
Provide and ground a product tank for A and B components, a tank for flushing
agent and an empty tank for return flow.
Connect the system to the air supply.
b_02817
S
B
A
Rücklauf
A+S
B+S
NOTICE
Magnetic fields!
Danger of damage to electronic devices and magnetic data carriers.
Ensure that electronic devices and magnetic data carriers are removed from the
danger area.
B_02816
A
B
S
Rücklauf
A+S