16
VERSION 01/2021
ORDER NUMBER DOC2422004
TOPFINISH Bell 1S ECH
Ensure that the pipe joints, hoses, equipment parts and connections are
permanently, technically leak-proof:
– Periodic preventative maintenance and service (replacing hoses, checking
tightness of connections, etc.).
– Regular monitoring of leaks and defects via visual inspection and odor testing,
e.g., daily before commissioning, at the end of work or weekly.
Ensure that maintenance and safety checks are performed regularly.
In the event of defects, immediately bring the device or system to a stop and
arrange to have repairs carried out immediately.
4.1.3 PERSONNEL QUALIFICATIONS
Danger due to incorrect use of device!
Risk of death due to untrained personnel.
Ensure that the operating personnel has been instructed by the operator in
accordance with the operating manual and the operating instructions. The device
must only be operated, maintained and repaired by trained personnel. Refer to the
operating instructions for information about the required personnel qualifications.
4.2
SAFETY INSTRUCTIONS FOR THE PERSONNEL
Always observe the information in this manual, particularly the safety instructions
and the warning instructions.
Always follow local regulations concerning occupational safety and accident
prevention regulations.
In electrostatics applications: anyone who belongs to a risk group according to EMF
Directive 2013/35/EU (e.g., those with active implants), must not enter the high-
voltage area.
4.2.1 PERSONAL SAFETY EQUIPMENT
Danger due to dangerous fluids or vapors!
Serious or fatal injuries due to inhalation, swallowing or contact with the skin or eyes.
When preparing or working with lacquer and when cleaning the device, follow the
working instructions of the manufacturer of the lacquers, solvents, and cleaning
agents being used.
Take the specified protective measures. In particular, wear safety goggles, protective
clothing and gloves, as well as hand protection cream if necessary.
Use a mask or breathing apparatus if necessary.
For sufficient health and environmental safety: Operate the device in a spray booth
or on a spraying wall with the ventilation (extraction) switched on.
Wear suitable protective clothing when working with hot products.
Danger due to noise pollution!
Hearing damage due to noise pollution.
Wear ear protection.