![WAGNER SPRINT XE Translation Of The Original Operating Manual Download Page 9](http://html1.mh-extra.com/html/wagner/sprint-xe/sprint-xe_translation-of-the-original-operating-manual_4516818009.webp)
Operating manual Manual Powder System SPRINT XE
3 Identification
Order number 2354920 | Edition 01/2023
9
3 IDENTIFICATION
3.1 EXPLOSION PROTECTION IDENTIFICATION
3.1.1 Trolley identification
Device type
Airfluid XE trolley/60L XE trolley
manufacturer
Wagner International AG
9450 Altstätten
Switzerland
II 3 D Ex h IIIB T100°C Dc
CE
European Communities
Ex
Symbol for explosion protection
II
Device class II
3
Category 3
D
Ex-atmosphere dust
Ex
Ignition protection class
h
Ignition protection class for non-electrical devices
IIIB
Explosion group (dust group)
T100°C
Temperature class, maximum surface temperature < 100 °C; 212
°F
Dc
Device protection level, suitable for use in Zone 22
3.1.2 Control unit identification
The device is suited for use in potentially explosive areas, in accordance with Test Certificate
PTB 12 ATEX 5001.
Device type
EPG-Sprint XE control unit
manufacturer
Wagner International AG
9450 Altstätten
Switzerland
0102
II 3(2) D IP64 80°C
CE
European Communities
0102
Number of notified body which issues the recognition of quality
assurance in production.
Ex
Symbol for explosion protection
II
Device class II
3
Category 3 (zone 22)
(2)
Impact on equipment of category 2
D
Ex-atmosphere dust
IP 64
Protection class IP64
80°C
Temperature class, maximum surface temperature < 80 °C;
176 °F