26
VERSION 01/2020
ORDER NUMBER DOC2397091
SprayPackE
5.6.1 TERMINAL ASSIGNMENT
Terminal block X40: Current supply 3P+N+PE 230/400 V 50/60 Hz
Address
Terminal
Signal
Description
X40:1
up to 4 mm² L1
Current supply, 1rd phase
X40:2
up to 4 mm² L2
Current supply, 2rd phase
X40:3
up to 4 mm² L3
Current supply, 3rd phase
X40:4
up to 4 mm² N
Current supply, neutral conductor
X40:5
N
No connection
X40:6
up to 4 mm² PE
Current supply, PE ground conductor
Terminal block X10: Interface for emergency stop output, two channels
Address
Terminal
Signal
Description
X10:1
up to 2.5 mm² K1
EMERGENCY STOP circuit Channel 1
(open when triggered or device OFF)
X10:2
up to 2.5 mm² K1
EMERGENCY STOP circuit Channel 1
(open when triggered or device OFF)
X10:3
up to 2.5 mm² K2
EMERGENCY STOP circuit Channel 1
(open when triggered or device OFF)
X10:4
up to 2.5 mm² K2
EMERGENCY STOP circuit Channel 1
(open when triggered or device OFF)
Terminal block X20: Supply for EPG and movement
Address
Terminal
Signal
Description
X20:1-9
up to 2.5 mm² L-N-PE
230 VAC supply - EPG
X20:10
up to 2.5 mm² 24 VDC
DC operating voltage for frequency converter communication
X20:11
up to 2.5 mm² GND
GND of DC operating voltage
X20:12
up to 2.5 mm² L
230 VAC supply for frequency converter
X20:13
up to 2.5 mm² N
Neutral conductor
X20:14
up to 2.5 mm² PE
Ground conductor
The entire circuit can be found in EPLAN 2373527 CPE or EPLAN 2374695 CPE-S.